AAMA 711, 712, 713 - Flashing Flashcards

1
Q

This standard explains test method and performance acceptance criteria for mechanically attached flexible flashing products.

A

AAMA 712

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AAMA 712 explains test methods and performance criteria for 5 performance parameters, what are they?

Hint: Think about mechanical stressers and environmental ones.

A
  • Tensile Strength
  • Tear Resistance
  • Puncture Resistance
  • Low-Temperature Flexibility
  • Accelerated Ultraviolet Exposure
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Can self-adhered and mechanically attached flashing be combined on a single fenestration installation.

A

Yes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the standard used for determining the performance of self-adhering flashing products.

A

AAMA 711

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What properties of self-adhering flashing products are evaluated by AAMA 711?

(5 properties)
(Hint: Mostly properties unique to the composition and function of this material vs. paper flashing).

A
adhesion
compatibility
water penetration around nails
tensile strength 
cold temperature pliability
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

There are two types of product types classified by AAMA 711, what are they?
Define each one.

A

Type A. Adhere without primer

Type B. Primer required to pass ANY part of the requirements.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How does AAMA 711 suggest addressing the compatibility of adhesives used in self-adhering flashing?
(Hint: DART)

A

D - Using materials with DEMONSTRATED compatibility
A - Avoiding “or equivalent” specifications
R - get manufacturer’s RECOMMENDATIONS.
T - Mock-up TESTING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

AAMA 711 Tests adhesion by applying the flashing to what four sample materials?

A

OSB
Anodized Aluminum
Vinyl
Wood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is adhesion tested per AAMA 711?

A

24 hour ‘sit’

Pull off at 90 degree angle.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What standard is referenced by AAMA 711 for water-resistance around penetrations?

A

ASTM D1970

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What standards are referenced for testing of tensile strength in AAMA 711?

A

ASTM D412

ASTM D1970

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What standard is referenced by AAMA 711 for standards and testing of low temperature pliability?

A

ASTM C765/ASTM D1970

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What performance criteria must self adhered flashing pass for low-temperature pliability?

A

Must be bent around a mandrill at 0 degrees without cracking.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What force is applied to pull flashing off the substrate per AAMA 711 - ASTM D3330?

A

1.5 psi.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What three temperatures levels are used to test SAF adhesion after accelerated aging?

(These accelerated aging tests for both SAF and FAF are based on Celsius temperature thresholds and intervals)

A

Level 1 - 122 F
Level 2 - 149 F
Level 3 - 176 F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many heating/cooling cycles are included in the ASTM E330 accelerated aging peel-off test?
What are the temperature limits of the thermal cycling?

A

25 cycles

From 120 F to -40 F

17
Q

How is a SAF sample evaluated for adhesion and other changes after immersion?

(Hint regarding changes - No: SAC)
AAMA 711 - ASTM D3330

A
Pull off test at 1.5 PSI
No
  Swelling
  Appearance Changes
  Contour changes
18
Q

At what temperature is SAF tested for low-temperature flexibility?

A

Zero F.

19
Q

Per AAMA 714, FAF is tested for heat exposure at what 3 temperatures and duration?

(Hint, derived from Celsius)

A

122 (50 C + 15 Deg. C)
149
176

Duration is 7 days at each level.

20
Q

What standard is referenced for testing for adhesive strength in FAF products.

A

ASTM C794

21
Q

FAF heat exposure test must be followed by a peel-off test after what additional conditioning of the samples?

ASTM C794

A

Freeze-thaw cycling.

22
Q

What does ASTM C794 freeze-thaw cycling entail:

A

24 hours cure, then, 10 cycles of:
8 hours at 120 deg
16 hours at -40 deg.

23
Q

What ASTM standard is referenced by AAMA 714 regarding the ability of FAF to bridge cracks or gaps?

A

ASTM C1305

24
Q

AAMA 714 provides an optional classification for FAF adhesion to surfaces in what condition?

6.2

A

Damp surfaces

25
Q

What standard is referenced by AAMA 714 for testing of water penetration around fasteners?

A

AAMA 711

26
Q

Samples for freeze-thaw, elevated temperature exposure and water immersion exposure testing per AAMA 714 are prepared on what substrate?

A

concrete mortar slabs.

27
Q

In addition to bonding as required for dry surfaces, FAF intended for application on damp surfaces, must also demonstrate this attribute:

A

Vapor permeability.

28
Q

The AAMA 714 test for crack bridging includes what conditioning of the sample per ASTM C1305?

A

14 day cure
7 days at 70 C (158 F)
24 hours at -26C (-15F)

.

29
Q

How many cycles of movement is the sample subjected to per ASTM C 1305?
How much movement is created for the test?

A

10 at least.

3.2 mm

30
Q

This standard pertains to the attributes and testing of aerosol foam sealants.

A

AAMA 812

31
Q

What requirements for dimensional stability are included in AAMA 812 and how are they tested?

A
No more than 10% variation
After heating at 
104 F
86 F
-4 F 
at 7 and 14 day intervals