symptoms of acute CO exposure can present at what CoHb levels?
3%-24%
OSHA recommended max allowable COHb level for a healthy worker is __.
5%
What is the CO Threshold Limit Value according to the American Conference of Governmental Industrial Hygienists?
25 ppm as a TWA for a 8-hour workday/40-hour work week
According to EPA, CO levels in homes with gas stoves varies from ____. Levels near properly adjusted stoves are ____, and levels near poorly adjusted stoves may be ___.
.5 to 5 ppm
5 to 15 ppm
30 ppm or higher
What are the CPSC CO Alarm standards?
- MUST sound at exposures expected to reach 10% COHb in heavily exercised individual
- CANNOT sounds when exposed to 30 ppm for few than 30 days, or at 70 ppm for less than one hour.
Occupants will not allowed to remain in or return to a structure with CO readings over
25 ppm
SCBAs will be worn with CO readings over
25 ppm
Complete the ___ for documentation when mitigating a CO Incident.
AFD CO Checklist
Potential sources for elevated CO:
gas appliances
internal combustion engines
charcoal grill
If the source of elevated CO levels cannot be found, advise the resident to ___.
call an HVAC co immediately
CO alarms manufactured before ___ should be replaced.
oct 1, 1998
AFD CO Checklist can be found where?
SpecOps page