A320 Oral Prep Flashcards
How do you charge the batteries if the voltage is below 25.5?
Select EXT power ON; Place BAT PBs ON; Check ECAM ELEC page that contactors
are closed and batteries charging.
What does a FAULT light in a battery pb indicate?
Charging current for the corresponding battery is outside normal limits.
With the FAULT light illuminated in the battery pb is the battery contactor open or closed?
Open
With the battery PBs selected what busses are powered (assumes batteries are the only power source)?
HOTBATTERYBUS1and2 are always powered.
DC BATTERY BUS
What is the difference between a green CB and a black CB?
GreenCBsaremonitoredbytheFWS.IfagreenCBisoutformorethan1minute,
then an ECAM will be generated.
o Black CBs are not directly monitored by the FWS. In this case the component
protected by a black CB is monitored directly by the FWS.