A201.5 High-Rise Fires Flashcards

1
Q

A High-Rise Alarm complement shall consist of _________ for investigating a report of a high-rise fire and mitigating incipient fires

A

four Engines, three Aerial Apparatus, one Rescue unit, two Battalion Chiefs, and a Safety Chief.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The first arriving ________ or _________ will assume Inside Truck and serve as the Division Supervisor on the fire floor until the arrival of a chief.

A

Aerial Apparatus
Rescue Unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Inside Truck is responsible for truck work on the fire floor including

A

locating the fire,
forcing entry for access to the fire,
primary search in the fire area,
salvage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The first arriving initial attack team will respond to the _____________ to check the ___________ , obtain ____________ , and obtain _____________

A

Fire Control Room
fire alarm panel
building keys
plug-in phones

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

initial attack teams communicate their actions and give size-up reports from five locations:

A

i. The exterior upon arrival; # of stories and if fire/smoke is showing.
ii. The Fire Control Room; including the information obtained from the fire alarm panel.
iii. The Fire Attack Stairwell; including the designation of the Attack Stairwell and smoke conditions within that stairwell.
iv. The fire floor; including confirmation of the fire floor #, the fire/smoke conditions on that floor and actions being taken.
v. The fire room/apartment; including the fire room/apartment number and actions being taken

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Other information such as status of __________ , if __________ are being utilized, whether or not a ______________ is operating, etc. should also be conveyed

A

occupant evacuation
elevators
sprinkler system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Tests have proven that PPV fans can be used to pressurize the Attack Stairwell to prevent the products of combustion from entering. This is best accomplished by placing one fan blowing into the stairwell at_______ and a second fan blowing into the stairwell ______________.

A

the bottom
three floors below the fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hoselines should initially be placed on the floor of fire origin, and the fire should be attacked at that area. Secondary hoselines should then attack any extension ___________

A

on the floors above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hoselines should initially be placed on the floor of fire origin, and the fire should be attacked at that area. Secondary hoselines should then attack any extension ___________

A

on the floors above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Secondary hoselines should then attack any extension on the floors above. Except in _______ circumstances, fire cut-off on floors above the origin floor should not be undertaken unless the fire ____________.

A

Rescue
below is under control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The second arriving Aerial Apparatus or Rescue Unit will assume the function of _______ . This group is responsible for operations above the fire floor(s)

A

Recon Group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Recon Group should use an Evacuation Stairwell and respond above the floor(s) to search for _________ and check for __________.

A

Occupants
fire extension

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The third arriving Aerial Apparatus or Rescue Unit Officer will assume _________ and the driver will assume __________.

A

Logistics
Systems Control Unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Logistics Chief is initially responsible for all activities that support fire attack, this includes

A

Water Supply,
Lobby Control
and
Systems Control.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Systems Control Unit is responsible for staffing the

A

Fire Control Room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Systems Control Unit: After Lobby Control has secured entry/exit points and prevented occupant re-entry _______

A

, silence any audible alarms with Command approval.

16
Q

The fourth arriving Aerial Apparatus or Rescue Unit will ascend with the _______ and will assume ____________ fire floor

A

RIC equipment
Staging two floors below the

17
Q

the on-call Prevention Inspector should be assigned to

A

the Systems Control Unit

18
Q

Department Engineers should be assigned to

A

the Planning Section as Technical Specialists

19
Q

The second arriving Rescue Captain will assume the function of the __________.

A

RIC Group Supervisor

20
Q

Upon upgrading to a 2nd alarm, the Logistics Section and all Companies reporting to Logistics should

A

switch to the assigned alternate channel

21
Q

A rule of thumb is to have _____ companies in reserve for each company committed to the fire attack.

A

two