652 - P1 (50Q) Flashcards
1
Q
Acceleration of curing by increasing the temperature above ambient, accompanied by forced air
circulation.
A
forced-curing
2
Q
An internal tank bottom lining may be deemed necessary if inspection shows that the minimum thickness of the bottom steel plate is less
than ____________
A
0.100 inch (2.5 mm).
3
Q
. A properly applied tank bottom lining may provide _______ years of service life in a particular product.
A
10 to 20
4
Q
Tank bottom linings can generally be divided into two
classes: thin Þlms (___mils or less) and thick Þlms (greater than __ mils).
A
20, 20