3.7 - Fire, Smoke or Fumes Flashcards
FIRE DETECT
Indication: CAS caution - Fire detector
Condition: A fault in the fire detection system has occurred
ON GROUND
- Engine - Do not start or shutdown
- Maintenance is required
IN FLIGHT
- Engine - Check Indications
- Land as soon as practical
ENGINE FIRE
Indication: CAS warning - Engine Fire and callout “FIRE”, possible smokes
ON GROUND
- PCL - idle
- Condition lever - CUT-OFF/FEATHER
- ACS EMER shutoff - PULL
- FUEL EMERG shotoff - latch down pull up
- Radio - EMGCY call
- MASTER POWER - off
- Parking brake - OFF
- Evacuate
- extinguish
IN FLIGHT
- Engine power - Reduce to minimum acceptable
- ACS EMGCY shutoff - pull
- Main oxy lever - conffirm ON
- Crew oxy masks - ON (Follow procedures to don the masks)
- crew oxy - EMGCY
- PAX OXY - ON
- MFD PAX OXY - Confirm ON
- Pax - instruct don masks
- Aircraft - check fire
if confirmed that fire exists
a. FUEL EMGCY shutoff - latch down pull up
b. Condition Lever - CUT-OFF/FEATHER
if smoke evacuation is required
a. ACS EMERGCY shutoff - PULL
b. CABIN PRESSURE - DUMP
when cabin differencias is zero
c. DV WINDOW - OPEN
d. FAN VENT - LOW
COCKPIT/CABIN FIRE, SMOKE OR FUMES, SMOKE EVACUATION
- MAIN OXY LEVER - confirm ON
- CREW OXY MASK - ON
- CREW OXY - EMGCY
- PAX OXY - ON
- MFD PAX OXY - CONFIRM ON
- PAX - INSTRUC DON MAKS
- Iniciate descente to below 10.000FT or MSA
- Proceed to the nearest airfield
if smoke evacuation is required
a. ACS EMER shut off - Pull
b. CABIN PRESS - Dump
when cabin pressure difference is zero
c. DV Windon - Open
d. Vent fans - low