303 - DCPO Flashcards

1
Q

Which condition is set when the ship is entering or leaving port in wartime?

A

Condition ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which open Circle designated fittings must be guarded so they can be closed immediately?

A

Circle ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which condition allows fittings above the waterline to remain open to improve ventilation and habitability?

A

Modified condition YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

All compartments must have a compartment check off list permanently posted __________?

A

In clear view of the space access, within 5 feet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

For compartments having dual responsibility - such as squadron work and living spaces on air capable ships, which will be listed on the CCOL?

A

Both parent division and squadron alpha numeric designator will be listed on CCOL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The Ocenco EEBD is rated by NIOSH for a minimum of __________ operating time.

A

10 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Standard navy fire hose is available in sizes ____________ diameter in ________ lengths.

A

1-1/12 through 4; 50 foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Pipe Diameter 2”-6”, Stencil Size?

A

1” Stencil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is a hoses minimum distance off the deck?

A

Minimum 6” off deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hoses Hydrostatic Date?

A

Month/Year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Photo Luminescent Door Markings Specs should be?

A

12” Top, Bottom, & Hinge Side

18” Handle Side (or cut to fit).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The bottom edge of the lowest egress route markings is to be no lower than _____ above deck level. The uppermost marking is to be no higher than _____ from the deck.

A

12 inches; 36 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The word “EXIT” is to be placed on each door in a normal egress route, ____ above the bottom of the door.

A

6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Set when the ship is in almost no danger of attack or natural hazard.

A

XRAY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Set and maintained at sea, when entering or leaving port during peacetime, in port during peacetime (other than normal working hours) and in port during wartime.

A

YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Closures and fittings above the waterline may be left open to improve accessibility and habitability.

A

Modified YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Set during general quarters.

A

ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Provides a higher survivability stance than condition YOKE, is less restrictive than ZEBRA and will more readily allow the accomplishment of certain operation requirements.

A

Modified ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

May be opened without special permission.

A

Circle X-RAY and Circle YOKE

20
Q

The CO may authorize ___ closures and fittings to facilitate the feeding of the crew and to allow the use of selected sanitary spaces.

A

Circle ZEBRA

21
Q

Fittings must be closed during darken-ship to prevent light from showing outside the ship.

A

Dog ZEBRA

22
Q

Serve vital piping and ventilation systems. Fittings may be open and operating regardless of the material condition of readiness set.

A

WILLIAM

23
Q

Which NSTM covers fire extinguishers?

A

NSTM 555

24
Q

Which NSTM covers DC markings?

A

NSTM 079 vol 2

25
Q

Which NSTM covers piping?

A

NSTM 505

26
Q

Which NSTM covers ventilation?

A

NSTM 510

27
Q

Which NSTM covers fittings, closures, doors, and hatches?

A

NSTM 600

28
Q

When do we set Circle William?

A

During a prolonged GQ and during a CBR attack

29
Q

When do you log discrepancies in closure log?

A

If the closure is less than 24hrs

30
Q

When do you log discrepancies in the inoperative log?

A

If the closure or inoperability lasts longer than 24hrs

31
Q

How long is the CO2 fire extinguisher good for without use?

A

12 years

32
Q

How long is the CO2 fire extinguisher good for when used?

A

5 years

33
Q

How much does the standard CO2 fire extinguisher weigh?

A

15lbs

34
Q

Which of the portable fire extinguishers has a gauge?

A

AFFF

35
Q

What percentage of the AFFF bottle is AFFF concentrate?

A

6% AFFF (2.5 gallons) 94% Fresh Water

36
Q

What pressurizes the portable PKP extinguisher?

A

CO2 cartridge

37
Q

What is the shelf life of the EEBD?

A

15 years

38
Q

How many settings are on the fire hose?

A

4

39
Q

What are the settings on the fire hose?

A

Wide V, Narrow V, Solid and Flush

40
Q

What is the firehose rating?

A

95 gallons inside ship and 125 outside

41
Q

How long is the hydrostatic testing for a firehose?

A

3 min test, 300 psi, good for 3 years

42
Q

Where does the hydrostatic test date go on a firehose?

A

6 in away from coupling

43
Q

Who do you notify when doing fire station maintenance?

A

DCA

44
Q

What are the dimensions of a bullseye?

A

12x15 in

45
Q

What types of build up occur in vents?

A

Light, moderate or heavy

46
Q

What markings are placed on ladderwells?

A

6in tape on each footfall and 6 1in strips on each handrail