303 - DCPO Flashcards

1
Q

Which condition is set when the ship is entering or leaving port in wartime?

A

Condition ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which open Circle designated fittings must be guarded so they can be closed immediately?

A

Circle ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which condition allows fittings above the waterline to remain open to improve ventilation and habitability?

A

Modified condition YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

All compartments must have a compartment check off list permanently posted __________?

A

In clear view of the space access, within 5 feet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

For compartments having dual responsibility - such as squadron work and living spaces on air capable ships, which will be listed on the CCOL?

A

Both parent division and squadron alpha numeric designator will be listed on CCOL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The Ocenco EEBD is rated by NIOSH for a minimum of __________ operating time.

A

10 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Standard navy fire hose is available in sizes ____________ diameter in ________ lengths.

A

1-1/12 through 4; 50 foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Pipe Diameter 2”-6”, Stencil Size?

A

1” Stencil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is a hoses minimum distance off the deck?

A

Minimum 6” off deck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hoses Hydrostatic Date?

A

Month/Year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Photo Luminescent Door Markings Specs should be?

A

12” Top, Bottom, & Hinge Side

18” Handle Side (or cut to fit).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The bottom edge of the lowest egress route markings is to be no lower than _____ above deck level. The uppermost marking is to be no higher than _____ from the deck.

A

12 inches; 36 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The word “EXIT” is to be placed on each door in a normal egress route, ____ above the bottom of the door.

A

6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Set when the ship is in almost no danger of attack or natural hazard.

A

XRAY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Set and maintained at sea, when entering or leaving port during peacetime, in port during peacetime (other than normal working hours) and in port during wartime.

A

YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Closures and fittings above the waterline may be left open to improve accessibility and habitability.

A

Modified YOKE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Set during general quarters.

A

ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Provides a higher survivability stance than condition YOKE, is less restrictive than ZEBRA and will more readily allow the accomplishment of certain operation requirements.

A

Modified ZEBRA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

May be opened without special permission.

A

Circle X-RAY and Circle YOKE

20
Q

The CO may authorize ___ closures and fittings to facilitate the feeding of the crew and to allow the use of selected sanitary spaces.

A

Circle ZEBRA

21
Q

Fittings must be closed during darken-ship to prevent light from showing outside the ship.

22
Q

Serve vital piping and ventilation systems. Fittings may be open and operating regardless of the material condition of readiness set.

23
Q

Which NSTM covers fire extinguishers?

24
Q

Which NSTM covers DC markings?

A

NSTM 079 vol 2

25
Which NSTM covers piping?
NSTM 505
26
Which NSTM covers ventilation?
NSTM 510
27
Which NSTM covers fittings, closures, doors, and hatches?
NSTM 600
28
When do we set Circle William?
During a prolonged GQ and during a CBR attack
29
When do you log discrepancies in closure log?
If the closure is less than 24hrs
30
When do you log discrepancies in the inoperative log?
If the closure or inoperability lasts longer than 24hrs
31
How long is the CO2 fire extinguisher good for without use?
12 years
32
How long is the CO2 fire extinguisher good for when used?
5 years
33
How much does the standard CO2 fire extinguisher weigh?
15lbs
34
Which of the portable fire extinguishers has a gauge?
AFFF
35
What percentage of the AFFF bottle is AFFF concentrate?
6% AFFF (2.5 gallons) 94% Fresh Water
36
What pressurizes the portable PKP extinguisher?
CO2 cartridge
37
What is the shelf life of the EEBD?
15 years
38
How many settings are on the fire hose?
4
39
What are the settings on the fire hose?
Wide V, Narrow V, Solid and Flush
40
What is the firehose rating?
95 gallons inside ship and 125 outside
41
How long is the hydrostatic testing for a firehose?
3 min test, 300 psi, good for 3 years
42
Where does the hydrostatic test date go on a firehose?
6 in away from coupling
43
Who do you notify when doing fire station maintenance?
DCA
44
What are the dimensions of a bullseye?
12x15 in
45
What types of build up occur in vents?
Light, moderate or heavy
46
What markings are placed on ladderwells?
6in tape on each footfall and 6 1in strips on each handrail