3. APU AND ELECTRICAL Flashcards
1
Q
Loss of APU
A
- Shut down affected APU.
2
Q
APU High EGT
A
- Take affected generator off line and shut down affected APU prior to reaching 1320 deg F.
3
Q
APU Engine Surge/Stall
A
- Depress affected generator key on UKB to OFF.
- Abort main engine start.
- Shut down APU if surging continues.
4
Q
Failure of APU Auto Shutdown
A
- Shut down affected APU.
- If APU fails to shut down, position T/R Pwr/B Pwr switch to OFF on affected APU.
- Go hullborne.
- Isolate affected APU fuel system.
5
Q
Loss Of APU Fuel Pressure
A
- Depress affected generator key on UKB to OFF.
- Shut down affected APU.
- Place TR/BATT Pwr switch to OFF.
6
Q
APU Low Lube Oil Pressure
A
- Depress affected generator key on UKB to OFF, and shut down APU prior to pressure reaching 6 psig.
7
Q
APU High Lube Oil Temperature
A
- Depress affected generator key on UKB to OFF, and shut down APU prior to temperature reaching 275 deg F.
8
Q
Loss Of Generator
A
- Depress affected generator key on UKB to OFF.
9
Q
Loss of Transformer Rectifier
A
- Verify other T/R has assumed DC load.
10
Q
Partial Loss of Electrical Power
A
- Monitor AC load.