2015 IRC Exam 4 of 4 (73-97) Flashcards
1
Q
73. What is the minimum size of an attic access opening? (p411 - R807.1) a. 18 X 24 b. 20 x 24 c. 22 X 30 d. 24 x 24
A
c. 22 X 30
2
Q
- What is the R value of the insulation that is placed between the first and second floor?
a. 13
b. 19
c. 22
d. 28
A
a. 13
3
Q
75. What is the gauge of metal to be used as flashing where the eave of a sloped roof intersects a vertical sidewall? (p413 - R903.2.1) a. 16 b. 22 c. 24 d. 26
A
d. 26
4
Q
76. What is the minimum slope of a roof if you wish to use clay and concrete roof tiles? (p418 - R905.3.2) a. 1 : 12 b. 1 ½ : 12 c. 2 : 12 d. 2 ½ : 12
A
d. 2 ½ : 12
5
Q
77. What is the minimum slope of a roof if you are using 9 x 13 asphalt shingles? (p417 - R905.2.2) a. 2:12 b. 3:12 c. 4:12 d. 5:12
A
a. 2:12
6
Q
78. How many fasteners are required per each wood shingle if used on the roof? (p420 - R905.7.5) a. 2 b. 3 c. 4 d. no requirement
A
a. 2
7
Q
79. What is the minimum percentage of slope of a roof if you wish to use a coal tar builtup roof? (p422 - R905.9.1) a. 1 b. 2 c. 3 d. flat
A
a. 1
8
Q
80. What is the minimum class of roofing required for a school? (p413 - Top of Page) a. class A b. class B c. class C d. no requirement
A
c. class C
9
Q
- What size hearth extension would be needed if the size of the fireplace opening is 24 inches x 30 inches?
(p430 - R1001.10)
a. 20 inches in front of and 12 inches beyond both sides
b. 16 inches in front ofand 8 inches beyond both sides
c. 18 inches in front of and 6 inches beyond both sides
d. no requirement
A
b. 16 inches in front ofand 8 inches beyond both sides
10
Q
82. What is the minimum size of masonry that may be used in a fireplace firebox if no lining is used? (p427 - R1001.5) a. 8 inch b. 10 inch c. 12 inch d. no requirement
A
b. 10 inch
11
Q
83. The chimney flue lining shall not change shape or size within \_\_\_\_\_\_\_ inches when passing through floors or ceilings. (p432 - R1003.6) a. 2 b. 3 c. 6 d. 9
A
c. 6
12
Q
84. What is the minimum height of a chimney to be above a structure if it is 8 feet away from the ridge of that building? (p432 - R1003.9) a. 1 foot b. 2 feet c. 3 feet d. 4 feet
A
b. 2 feet
13
Q
85. All spaces between chimneys and floors and ceilings through which chimneys pass shall contain \_\_\_\_\_\_\_? (p435 - R1003.19) a. draftstopping b. fireblocking c. caulk d. no requirement
A
b. fireblocking
14
Q
- A two story, non-sprinklered apartment building of type V-B construction may be a maximum of _______ square feet excluding other area increase allowances.
a. 5,000
b. 7,000
c. 10,000
d. 14,000
A
d. 14,000
15
Q
87. The areas of buildings limited by table 506.2 shall be permitted to be increased if the minimum horizontal distance of the frontage is \_\_\_\_\_\_\_\_ft. (Diagram) a. 5 b. 10 c. 15 d. 20
A
d. 20
16
Q
- The floor area of an one story office building that is equipped with a fire sprinkler system throughout need not be limited if it is surrounded by side yards having a width of not less than ______ft.
a. 20’
b. 40’
c. 60’
d. no requirement
A
c. 60’
17
Q
- A structure that is built of Type IIA construction, 12 feet from the property line that has openings that need to be protected, shall not exceed _______ percent of the square footage of the wall.
a. 25
b. 45
c. 50
d. 75
A
b. 45
18
Q
90. What is the fire protection rating required to be of the wall between Rental shop 2 and rental shop 3? (Diagram?) a. 1 hour b. 2 hour c. 3 hour d. 4 hour
A
d. 4 hour
19
Q
91. A fire door located within a 4 hour rated fire wall between a rental shop and a retail sales store must have a rating of at least \_\_\_\_\_\_\_ hours. (Diagram?) a. 4 b. 3 c. 2 d. 1
A
b. 3
20
Q
- Where would a relief valve be needed when using an air admittance valve?
(p888)
a. where a horizontal branch is more than 4 branch intervals from top of stack.
b. the second floor of 4 story building.
c. the fourth floor where two fixture drains connect.
d. the third floor of a 4 story building.
A
a. where a horizontal branch is more than 4 branch intervals from top of stack.
21
Q
93. Concrete that is made with Type I or Type II Portland cement and is cured at 55 degrees rather than 40 degrees will be \_\_\_\_\_\_\_\_\_ (p888) a. stronger b. weaker c. unusable d. no difference
A
a. stronger
22
Q
- Systems of structural steel elements acting compositely with reinforced concrete shall be designed in accordance with what agency?
a. ASTM 35
b. AISC 360
c. ASCE 7
d. no requirement
A
b. AISC 360
23
Q
- The use of open-web steel joists and joist girders shall be in accordance with what agency?
a. ASTM
b. AISC
C. SJICJ
d. ASCE
A
C. SJICJ
24
Q
- Walkways and barriers provided for pedestrian travel in front of every construction site shall not be less than _______ feet wide and _______ feet tall.
a. 3, 8
b. 4, 8
c. 4, 9
d. 3, 9
A
b. 4, 8
25
97. In an attic or crawl space where entry is for service of utilities, foam plastic insulation shall be protected against _______ by 1.5 inch thick mineral fiber insulation.
a. termites
b. ignition
c. water damage
d. no requirement
b. ignition