2015 IRC Exam 1 of 4 (1-24) Flashcards

1
Q
1.  Who shall have authority to render interpretations of the code and adopt policies of a jurisdiction?
(p2 - 104.1)
a.  mayor 
b.  city manager 
c.  building official 
d.  zoning administrator
A

c. building official

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
2.  A permit is required to \_\_\_\_\_ a structure.
(p3 - 105.1)
a.  enlarge 
b.  demolish 
c.  move 
d.  all of the above
A

d. all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
3.  A permit is not required if \_\_\_\_\_\_ 
(p3 - 105.2)
a.  a homeowner does the work 
b.  a new contractor does the work 
c.  making minor repairs and alterations 
d.  making major repairs and alterations
A

c. making minor repairs and alterations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. When reroofing a structure what is required before starting a project?
    (p3 - 105.3)
    a. notify neighbors
    b. make written application to building official
    c. get a demolition permit
    d. No requirements
A

b. make written application to building official

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
5.  Who is to be notified when the reroof job is ready for inspection?
(p7 - 109.1) 
a.  owner 
b.  building official 
c.  architect 
d.  engineer
A

b. building official

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  1. What will occur if work is commenced before a permit is obtained?
    (p7 - 108.6)
    a. additional permit fees will be required
    b. a permit will not be granted
    c. a reduction of the permit fee will be assessed
    d. no action will be taken.
A

a. additional permit fees will be required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. A board of appeals shall be created to ___
    (p8 - 112.1)
    a. make changes to the code
    b. address problems with inspectors
    c. decide appeals of decisions made by building official
    d. limit the authority of the building official
A

c. decide appeals of decisions made by building official

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
8.  A \_\_\_\_\_\_ probably would not be a member ofthe board of appeals. 
(p9 - 112.3)
a.  a certified architect 
b.  a certified engineer 
c.  a pilot 
d.  a certified contractor
A

c. a pilot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
9.  What species of wood is not naturally resistant to decay?
(p20 definition)  
a.  northern pine 
b.  black locust 
c.  hem-fir 
d.  teak
A

b. black locust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
10.  What is the minimum live load requirement for a deck attached to a residential structure?
(Table 301.5)
a.  20 lbs per square foot 
b.  30 lbs per square foot 
c.  40 lbs per square foot 
d.  50 lbs per square foot
A

c. 40 lbs per square foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
11.  In combustible construction fire blocking is required and the material shall be made of\_\_\_\_" nominal lumber. 
(p54 - 302.11.2)
a.  1/2" 
b.  3/4"
c.  1"
d.  2"
A

d. 2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
12.  Draft stopping materials shall not be less than \_\_\_\_\_" or other approved materials. 
(p55 - 302.12.1)
a.  0.25"  sheetrock 
b.  0.50"  plywood 
c.  0.375"  wood structural panel 
d.  2"  nominal wood lumber
A

c. 0.375” wood structural panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
13.  Draft stopping shall be installed in attics and concealed roof spaces of occupant groups other than R-1, R-2, and R-3 so that any horizontal area does not exceed \_\_\_\_\_\_ square feet. 
(p55 - 302.12.1)
a.  1,000 
b.  1,500 
c.  2,000 
d.  3,000
A

d. 3,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
14.  The minimum net glazed area to provide natural light shall not be less than \_\_\_ percent of the floor area of the room served.
(p55 - 303.1)
a.  2 
b.  4 
c.  6 
d.  8
A

d. 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
15.  The maximum distance an escape or rescue window shall be above the floor is \_\_\_\_\_\_ inches. 
(p62 - 310.2.2)
a.  24 
b.  36 
c.  44 
d.  48
A

c. 44

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
16.  What is the minimum headroom height of a stairway?
(p63 - 311.7.2)
a.  7 ft. 
b.  6 ft. 8 inches 
c.  6 ft. 
d.  8 ft.
A

b. 6 ft. 8 inches

17
Q
  1. The corridor walls of a nightclub have carpet installed as a wall covering. What is the maximum allowable flame spread of this material?
    a. 200
    b. 75
    c. 50
    d. 25
A

d. 25

18
Q
  1. What percentage of structural members shall be tested for sprayed fire-resistant materials on each floor?
    (p50)
    a. 100
    b. 75
    c. 50
    d. 25
A

d. 25

19
Q
19.  What is the minimum width of a stairway serving an occupant load of 100 people?
(p63 - 311.7)
a.  36 inches 
b.  44 inches 
c.  60 inches 
d.  no requirement
A

b. 44 inches

20
Q
20.  A handrail shall not be less than \_\_\_\_\_\_ in. measured above the stair tread nosings. 
(p66 - 311.8.3.1)
a.  32 
b.  34 
c.  36 
d.  38
A

b. 34

21
Q
21.  What is the maximum height a handrail can be above the stair tread nosings?
(p64 - R311.7.8.1)
a.  42. 
b.  38 
c.  36 
d.  32
A

b. 38

22
Q
22.  A guard shall be installed on a porch where the walking surface is more than \_\_\_\_\_\_ in. above the grade below. 
(p66 - R312.1.1)
a.  30 
b.  24 
c.  16 
d.  12
A

a. 30

23
Q
23.  Wood siding shall have a clearance of \_\_\_\_\_\_ inches from the ground or grade. 
(p70 - R317.1.5)
a.  2 
b.  4 
c.  6 
d.  8
A

c. 6

24
Q
24.  The minimum clearance of a foundation where the sill plate is not treated or naturally resistant to decay, and no masonry is used shall be \_\_\_\_\_\_ inches to exposed ground. 
(p70 - R317.1.2)
a.  6 
b.  8 
c.  12 
d.  18
A

b. 8