17. Positioning aerial apparatus Flashcards
If the building is greater than five stories
The engine takes the outside position and Ariel parks next to the building
Places the maximum amount of stress on an aerial device and in some cases reduce its load carrying capacity
Long extensions in low angles
Electricity will Arc cross a gap as large as __ft
10 ft
$$$
The long-standing fire service standard has been to provide __ feet of clearance between the aerial device and overhead high-voltage lines energized from 600 to 50,000 V and __ feet of clearance for a high voltage transmission lines over 50,000 V
10 ft
50 ft
The apparatus is most stable when the aerial device is operated directly over the
Front of rear
Jackknifing
Greatest ability occurs when this angle is approximately __° from in line and the aerial device is extended away from this angle.
60°
Good stability occurs at angles up to 90°
Ideally, the truck should be operated in the ___ position with the aerial device directly in line to reduce stress
Uphill
The maximum loading for any unsupported aerial device occurs when operated at angles between ___ from horizontal
70° and 80°
$$$
Most railroad companies advise that vehicles be kept at least __ feet from the tracks when possible.
25 ft
Keep the aerial device at least 25 feet above the level of the rails