All pipe used in a gas installation should be what colour?
Black
Schedule 40 pipe may be used for pressure up to
125 psig
Which pipe can be buried underground w/o any coating
Type K, buried min. 18”
All gas hoses & hose fittings shall have a minimum pressure rating of
350 psig
The maximum allowable pressure drop on a low-pressure gas line system is
1” WC
The maximum allowable pressure drop on a high-pressure system is
50% of standing pressure
Drill holes must be located a minimum of
2 inches from any edge of a member
What must be applied to the male threads only, so that excess dope is forced out of the pipe instead of pushed into the pipe
Pipe dope
What tape is used for plumbing and is not approved for gasfitting?
white Teflon
Teflon tape must be applied how?
- wrapping it clockwise
- stretching it with a 50% overlap
- leaving the first 2 starter threads bare
Malleable iron bushings must reduce at least
2 or more pipe sizes
What is located in the gas pipe at the bottom of the final drop to an appliance?
Dirt pocket
Gaskets used in gas systems may not be natural rubber?
T or F
True as the gas tends to dissolve and break down the gasket
The minimum depth of the pocket is
3 inches
The fittings required to make up a dirt or drip pocket are:
a tee
a cap
a nipple