060201b Dual Vents Flat Vents and Residential Storm Drainage Flashcards
A flat vent is used when the vent must run __________ and __________ the flood level rim of that fixture.
Horizontal, Below
Two fixtures that use the flat vent are the __________ and the __________ .
Kitchen Sink, Tub
When a flat vent is installed, it must be equipped with a __________ .
Cleanout
The flat vent is sized as an __________ or __________ vent.
Individual, Dry
The table that is used to size a flat vent is Table __________ .
2.5.7.1
A flat vent should change to the __________ position as soon as possible.
Vertical
What are the limitations on distance when it comes to dual vents?
There are none
Minimum size rain water leader is __________ .
2”
Rainwater should not be piped to a sewage treatment plant because __________ .
Overload on the sewage treatment plant
A rainwater leader connected to a storm building drain does not require a __________ .
Trap
A rainwater leader connected to a combined building drain must be protected by a __________ .
Trap
Another name for an underground drainage system is __________ __________ .
Subsoil Drainage
If a new building must connect to an existing combined building sewer, the __________ and the __________ must not connect together closer than ___ metre(s) outside if the building.
Sanitary Building Drain, Storm Building Drain, 1
Maximum hight of rainwater leader clean out
3 Metres
Can you dual vent two dissimilar fixtures? If so how would you size it?
Yes you may dual vent 2 dissimilar fixtures as long as you size it according to the largest trap served