021.12 +.13 PROTECTION AND DETECTION SYSTEMS & OXYGEN SYSTEMS Flashcards
The bimetal strip detectors of an engine fire detection system are arranged in (series/parallel) and (open/close) during a fire.
The bimetal strip detectors of an engine fire detection system are arranged in (parallel) and (close) during a fire.
When a part of a continuous loop fire detection system is heated, its resistance (increases/decreases) and the leakage current (increases/decreases).
When a part of a continuous loop fire detection system is heated, its resistance (decreases) and the leakage current (increases).
Firewire detects a fire by detecting the (smoke/heat/flame) caused by the fire.
Firewire detects a fire by detecting the (heat) caused by the fire.
Considering CS-25, at least (…) fire extinghuisher discharger bottles are required per engine.
Considering CS-25, at least (2) fire extinghuisher discharger bottles are required per engine.
The name given tot the mode of operation in which 100% oxygen is inhaled on demand is (…).
The name given tot the mode of operation in which 100% oxygen is inhaled on demand is (100%).
In case of smoke in the cockpit, the crew oxygen regulator must be set to (normal/100%/emergency).
In case of smoke in the cockpit, the crew oxygen regulator must be set to (100%).
The opening of the doors giving access to the oxygen masks for the passengers is (pneumatic/electrical) for the gaseous oxygen system and (pneumatic/electrical) for the chemical oxygen system.
The opening of the doors giving access to the oxygen masks for the passengers is (pneumatic) for the gaseous oxygen system and (electrical) for the chemical oxygen system.
- Maximum cabin altitude is (…) ft.
- Warning when cabin alt. exceeds (…) ft.
- Masks release when cabin alt. exceeds (…) ft.
- Maximum cabin altitude is (8 000) ft.
- Warning when cabin alt. exceeds (10 000) ft.
- Masks release when cabin alt. exceeds (15 000) ft.
You can determine the amount of oxygen in a portable bottle by observing its (…).
You can determine the amount of oxygen in a portable bottle by observing its (pressure).
Emergency selector on an oxygen system is (demand-regulated/continuous flow) 100% oxyigen supply under (positive/ambient) pressure.
Emergency selector on an oxygen system is (continuous flow) 100% oxyigen supply under (positive) pressure.
Smoke hoods are available to aircraft crew and must last for at least (…) minutes.
Smoke hoods are available to aircraft crew and must last for at least (15) minutes.
The chemical oxygen generator supplies oxygen for about (…) minutes.
The chemical oxygen generator supplies oxygen for about (15) minutes.