XLDS Flashcards
What is the max operating depth for the XLDS system utilizing a 1/4” umbilical for the KM-97? MK-20 FFM?
KM-97: 132fsw
MK-20 150fsw
** 190fsw according to XLDS concept and use Narrative**
What are the parameters for the XLDS console relief valve utilizing a 1/4” umbilical?
390-400 psig
What amount (PSIG) of air is supplied to the diver worn ICS system for the XLDS console?
350-375 psig
What is the HP air supply system rated to? High pressure gauge…
3000-5000 psig
HP Gauge 0-5000 psig
What is the max outlet pressure for the XLDS Console regulator?
400 psig
What are the ranges of the reduction pressure gauge on the XLDS console?
0-600 psig
How long are the XLDS 1/4” umbilicals? What is the breaking strain of the communications/strength member?
330’ long
800 lbs lifting capacity
2200 lbs minimum breaking strain
What isthe inner diameter (ID) of the XLDS pheumpfathometer Hose
3/16”
What is the minimum XLDS Console supply pressure?
375 psig
What pressures does the diving supervisor request the console operator when managing flask switching?
Notify @ 500 psig switch @ 400 psig
State the psig parameters for the Intermediate Pressure (ISC) “over bottom” IAW the XLDS maintenance Manual?
150-170 psig
What is the cubic feet of the standard XLDS emergency gas system (EGS) bottle at RDLE?
.30 cu. ft
Normally, how often do you call out depths to the diving supervisor during decent? What about during ascent?
Depths ever 10fsw on decent and eery 5fsw on ascent
In your own words; define stage depth
The Pneumo reading taken when the diver are on the state or on the bottom prior to leaving bottom. Use it to compute distance and travel time to 1st stop or surface
In your own words; define Max Depth as it applies to a console operator
It’s the deepest depth obtained by the diver plus the Pneumofathometer correction factor