The O‐ring sealed fittings that connect the HP air supply to the RDC are designed to provide an air‐tight seal with minimal tightening of the fitting. Fittings should be installed hand‐tight and then lightly snugged using the effort of two fingers on a wrench (no more than a ___ turn past hand‐tight).
1/4
Umbilical blow down in OP1A occurs for ___ to ___ seconds.
5-10
The manifold is integrated with a ___ liter accumulator and manifold regulator system
.8
ICS reduces high velocity medium pressure breathing air (350 PSIG), from the umbilical, to between ___ PSIG and supplies it to the helmet or full face mask being used.
150-170
Breathing performance of the system allows breathing rates of up to __ RMV to depths of 100 FSW, and up to __ RMV to depths of 132 FSW for the KM97
90
75
Both the positive and non-positive pressure AGA FFM, can be used at work rates of __ RMV, to depths of 150 FSW.
75
The HP air supply system is rated for up to ___ psig service with properly rated fittings.
5000
The flow capability of the high-pressure system, enables standard SCUBA Cylinders, to be used as low as ____ PSIG, before Cylinder switch-out is necessary.
380
The console hand regulator is rated for a maximum inlet supply pressure of ____ PSIG, and a maximum outlet pressure of ___ PSIG.
5000
400
What is the console low pressure relief valve set to?
390-400psig
The XLDS with 1/4” umbilicals and diver worn manifold compensating system, has a normal umbilical restriction, to a maximum length of ____.
330’ (100 meters).
The 1/4” I.D. supply umbilical has a design pressure of ____ psig, and is rated for a normal maximum system working pressure of ___ psig.
1500
400
The strength member has a safe lifting capacity of ___ lbs, and a minimum breaking strength of ___ lbs.
800
2200
The Pneumofathometer Hose is made from black nylon plastic, ___” I.D. rated, for a maximum internal pressure of ___ PSIG.
3/16”
200
How much does the XLDS console weight?
87lbs
Console should not be used at pressures greater than ___ psig, with the “A” Yoke or ___ psig with DIN fittings
3500 Yoke
4350 DIN fitting
The recommended lubricant for XLDS is _____.
Christo‐Lube.
Very minor leaks at PIPE THREADED joints, that cause a drop of gauge pressure of no more than ___ PSIG in ten minutes, with the supply isolated at the HP blocks as noted on each of the high‐pressure gauges, do not require immediate re‐sealing. (doesn’t apply to o-ring fittings.)
10
What are the standard hand-load regulators used in the XLDS console?
Aqua Environments® model 873 piston type
The number one cause of leakage in the high‐ pressure regulator, _______.
is a dirty corroded HP seat
When installing a new high pressure valve assembly, in regulator body. Tighten to ___ inch lbs
80-100
Diver cross-connect valves are torqued to ___ inch lbs
60.
Tighten all console clamp blocks to __ inch lbs.
40 inch lbs
In normal use, the ICS regulator should be completely overhauled, at least every __ months or less.
36
ICS Regulator Rebuild
Insert the piston assembly with the piston into the regulator body, and thread the piston cap into the body, until it bottoms out then tighten to ___ inch lbs.
150
ICS Regulator Rebuild
A maximum of ___ shims may be used only. More shims means the spring needs to be replaced.
03
Dive Lab recommends all XLDS system gauges as well as support gauges be compared at least every __ months using certified master gauges.
24
Allowable error for the submersible gauges is no more than _% full scale.
3%