Wire Off Procedure Flashcards
1
Q
Wire Off Procedure
(Detailed)
A
- STEP BACK – State you need to ‘ENACT WIRE OFF PROCEDURE’
a. Take PHOTO of:
Wire
Host
Context
Prints - Inform D-SIM (You have found a wire off) and Request:
a. AWC
b. 2nd Competent Person (To attend site) - ISOLATE (Preferably after the Capacitor)
- Gather sufficient EVIDENCE for AWC:
a. Hand Trace (highest form of proving)
b. Identify Physical Attributes:
Cable Type
Size / Length
Colour
Labelling
Numbering - Remove Isolation (REINSTATE Power)
-
ELECTRICALLY PROVE:
a. Test both sides to Earth (1 = 100v / 1 = 0v)
b. Test Wire to Host (To prove Host is NX Potential)
Break circuit BX SIDE to lose Voltage proving wire is part of circuit (Closest to wire)
Break circuit NX side to lose Voltage Proving host is part of circuit (Closest to Host) -
PRE – Wire Count (With 2nd Competent Person)
a. Must be INDEPENDENT / Diverse checking (Do not lead)
b. YOU = Check Prints - HE/SHE = Counts at Terminal
c. Confirm Discrepancies (Ask to Repeat) - Confirm AWC issued with D-Sim (Request AWC number)
- ISOLATE
-
RECONNECT Wire to Host (Take picture)
a. Clearly LABEL:
Date
Name - POST – Wire Count (HE/SHE checks work)
- REINSTATE Power (Observe Track Pick-up)
- Clear AWC – REQUEST NIGHT CHECK
2
Q
Wire Off Procedure
(Simple)
A
You discover a wire off!
- ENACT WIRE OFF PROCEDURE’
- Inform D-SIM - AWC, 2nd Competent Person
- ISOLATE
- Gather EVIDENCE for AWC:
- Remove Isolation
- ELECTRICALLY PROVE:
- PRE – Wire Count (With 2nd Competent Person)
- Confirm AWC number
- ISOLATE
- RECONNECT Wire to Host (LABEL)
- POST – Wire Count (HE/SHE checks work)
- REINSTATE Power (Observe Track Pick-up)
- Clear AWC – REQUEST NIGHT CHECK