WELL Questions Flashcards
Which environmental conditions must be measured within 1.6 km (1 mile) of a building for Part 2: Outdoor Air Measurement of Feature 19, Operable Windows?
Ozone, PM10, temp, Humidity
What DBA that must be measured at the nearest workstation if a sound masking system is used in open work spaces?
45-48
When may a project team submit an alternative adherence path proposal for preapproval?
Before or after registration
All lighting except decorative has to dim to what % for dimming controls?
20% when not occupied
F56 Solar Glare Control applies to what glaizing?
Daylight - 7’ or higher
What type of on-site assessment is required for active furnishings?
Spot Check
What are the 3 parts of Integrative design?
Charette, development plan, stakeholder orientation
What procedures must be addressed in the written policy for Feature 35, Periodic Water Quality Testing?
Length of time records must be kept, remediation plan for unacceptable conditions
Daylight Modeling, requires spatial daylight autonomy (sDA300,50%) to be achieved to what percentage
55%
If a sound masking system is used in an enclosed office space, what is the sound level range (in dBA) that must be measured at the nearest workstation?
40-42
What is the requirement for pesticides and herbicides used on plants per Feature 10, Pesticide Management?
Hazard Tier 3
Which precondition in the Air Concept requires an assessor to complete a performance test after occupancy as an independent means of verifying that the building meets critical air quality requirements?
F1 Air Quality Standards
What is the default occupancy that should be used for Features pursued for Core and Shell projects and which are intended to impact all occupants?
250 sq ft / person
What is the method of documentation or performance verification for Part 2: Glare Minimization of Feature 55, Electric Light Glare Control?
A letter of assurance from the architect
What percentage of the floor area in all offices and other regularly occupied spaces must meet ASHRAE Standard 55-2013 when hydronic radiant heating and/or cooling systems or electric radiant systems are used?
50%