1
Q

What is a fire separation?

A

A construction assembly that acts as a barrier against the spread of fire and smoke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is a Fire Resistance Rating (FRR)

A

Time in hours or minutes that an assembly can withstand the passage of fire and transmission of heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the FRR for a firewall?

A

2 or 4 hour requirements

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does a fire rated steel floor require?

A

-requires to spray fireproofing or GWB encasing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How are concrete slabs fire rated?

A

By minimum thicknesses and minimum rebar cover.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the typical FRR for Concrete Shafts for exit stairs or elevators?

A

1 or 2 hours, usually matches required floor separation rating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the steel stud sizes?

A
always 32mm deep.
32x41
32x64
32x92
32x152
32x203
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is used in steel stud framing at the underside of a slab?

A

-deflection head track

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the required gap at floor when installing GWB for steel stud framing?

A

10mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is required for fire rated walls?

A
  • Type X board
  • continuity and edge seal
  • dampers in duct openings at walls
  • fire stopping to penetrations
  • closing doors
How well did you know this?
1