Week 2 Flashcards
1.The company commander is responsible for maintaining a currently accurate list of tools and equipment carried on vehicles and apparatus. Where is this list maintained?
In the UFS and on the rig. Regs 13
Who does the company commander request permission from to test pumpers for drafting water?
DC. Regs 13
How much extra hose are Engine Companies required to carry on the apparatus?
Not less than 3 lengths 2 ½” and not less than 3 lengths of 1 ¾”. Plus each engine shall ensure that an extra length of 1 ¾” with nozzle is carried on the apparatus. Regs 13
How much extra hose are Ladder companies required to carry on the apparatus?
Not less than 3 lengths 1 ¾” PLUS the nozzle. Regs 13
When are the motors and pumps of special unit apparatus tested?
Mondays on the 9x6 tour. Regs 13
According to regulations, when are aerials, tower ladders and portables given a thorough inspection?
Monthly. Regs 13
Procuring the meal is limited by what regulations?
45 minutes within first due area. Regs 13
When the apparatus is OOS who is notified?
Dispatcher, BC, DC. Regs 13
When apparatus hasn’t been returned to service within two hours, who is notified?
BC and DC. Regs 13
Your siren goes OOS, are you still available to respond?
Yes, need one AUDIBLE and one VISUAL warning device. Regs 13
Who notifies the shops when there is an apparatus defect or irregularity?
The officer. Regs 13
Hose is hung in the tower by which coupling?
Male. Regs 13
T/F The LCC can leave the rig in PTO if he is going to climb the aerial for a rescue.
False. If the controls are left unattended PTO shall be disengaged. Regs 13
Motors and pumps of special or spare apparatus shall be tested for how long?
15 minutes. Regs 13
Water in the boiler must be kept at what height? When is it checked?
3/4, immediately after the 0900 and 1800 roll calls. Regs 13
When can members enter a female facility in quarters?
Cleaning, maintenance, as directed by company commander. Regs. 13
How many supervisors per child are required for Third and Fourth grade classes?
1 to 15. Regs 19
How many supervisors per child are required for Fifth grade an up classes?
1 to 30. Regs 19
How many supervisors per child are required for classes below third grade?
1 to 4. Regs 19
How many supervisors are required for a scout troop visit?
1 to 20. Regs 19
How long are school visits permitted for and what is the time frame?
1 hour, 9 to 5. Regs 19
When are doors, guards and lights at pole hole openings inspected?
Daily. Regs 19
According to Engines 2, what specific topics should be discussed between Officer and ECC after roll call? More than one.
General response routes/modifications.
Road and weather conditions.
Dangerous areas or intersections. Engines 2
What basic functions should every engine member be able to perform?
Put rig in pumps.
Connect to hydrant.
Charge and maintain hoseline. Engines 2
What may be delegated by the engine officer to the nozzle team?
DECALS. Engines 2
All members going above the fire should communicate their identity to whom?
Second engine officer. Engines 2
Who is responsible to monitor department radio for BC or DC?
Second engine ECC. Engines 2
Firefighters intending to decline RSOT must notify the officer on duty when?
0900 the day before the 9x or 6x.
Hydrants and hydrant street shut offs close in which direction?
Counter Clockwise. TB Em 3
How many turns are required to shut off a hydrant street shut off?
17 turns counter clockwise. TB Em 3
After how many turns of a hydrant street shut off will you begin to see a noticeable decrease in water flow?
About 12 full turns. TB EM 3
What is the height of the cockloft nozzle?
6’3” TB Tools 7 DS 18
The OST’s on the cockloft nozzle increase the reach of the street to in excess of what footage?
Excess of 60’ TB Tools 7 DS 18
What is the discharge rate of the cockloft nozzle?
125 gpm. TB Tools 7 DS 18
What is the preferred location for use of the cockloft nozzle?
Immediately inside the apartment door. TB Tools 7 DS 18
How big of a hole is needed to utilize the cockloft nozzle?
3’ x 3’ TB Tools 7 DS 18
When utilizing the cockloft nozzle, what is the minimum clearance needed between the top of the ceiling joists and the bottom of the roof joists.
Minimum of 4” TB Tools 7 DS 18
Who can order the operation of the cockloft nozzle?
Chief officer. TB Tools 7 DS 18
When is the cockloft nozzle inspected?
Visually inspected weekly. TB Tools 7 DS 18
At a 10-77 who is responsible to bring the HRN to the command post?
5th due engine. TB Tools 7 DS 17
When is the 1 1/8” MST tip on the HRN checked?
Weekly during MUD and BEFORE use. TB Tools 7 DS 17
As it’s supplied by a 2 1/2” hoseline, the HRN will produce flows of what gpm and psi?
200-225 gpm at 50 psi. TB Tools 7 DS 17
What pressure is supplied at the outlet gauge when three lengths of 2 1/2” hose are stretched to the HRN?
70 psi. TB Tools 7 DS 17
What pressure is supplied at the outlet gauge when four lengths of 2 1/2” hose are stretched to the HRN?
80 psi. TB Tools 7 DS 17
Is the supply line to the HRN attached before or after the nozzle is slid outside the window?
Before. TB Tools 7 DS 17
When it is necessary to extinguish multiple rooms of fire with the HRN, which room do you start with?
Start with the window the wind is blowing into. TB Tools 7 DS 17
Where is the shutoff placed when the HRN is to be put into operation?
One length back. TB Tools 7 DS 17
When does officer supervising nozzle operations notify IC the nozzle is in position and ready for use?
When water has been started and is at the shutoff. TB Tools 7 DS 17
When is the combination nozzle system inspected?
Visually, weekly. TB Tools 7 DS 19
What is the range of elevation with the Akron New Yorker Multiversal Nozzle?
90 degrees above to 15 degrees below the horizontal. TB Tools 17
If you are attempting to lower the Akron New Yorker Multiversal Nozzle below _______ degrees, you need to pull the pin.
35 degrees. TB Tools 17
T/F If adequately secured by the proper ropes you can operate the Akron New Yorker Multiversal Nozzle below the horizontal.
False. Only operate below the horizontal in the truck mount. TB Tools 17
What are the size of the stacked tips on the Akron New Yorker Multiversal Nozzle?
1 1/4”, 1 1/2”, 2” TB Tools 17