Water Shuttle/Water Relay Flashcards
In a water relay, if a combination of LPP and appliance pumps are used, where should the LPPs be sighted?
Nearest to the water supply
How would an insufficient flow when relaying be improved?
Shortening distance between pumps using more intermediate pumps
Or
Increasing the diameter of the hose used
What does the distance between pumps in a relay depend on (list of 3)
The flow rate required
The diameter of hose lines between pumps
The contours of the relay route
How many lengths of 70mm apart can intermediate pumps be on a relay?
8 lengths on flat ground
6 lengths on a 10% incline
How many lengths of hoselayer 90mm apart can intermediate pumps be on a relay?
15 lengths on flat ground
12 lengths on an incline
At what bar pressure should an intermediate pump supply the foreground pump?
2 bar pressure.
This can be increased upon request up to a maximum of 15 bar.
The fireground pump operator must adjust the inlet valves to determine the correct flow and to try and maintain …(how much water in the Mark 3 flow meter)?
Between half and 3 quarters (when the autofill valve is fully open)