Series 3 Flashcards
What is the capacity of the appliance tank
1365 litres
What is the diameter of the yellow hose reels
22mm
How many litres per minute is the hose reel capable of producing?
230lpm
How long will it take one hose reel at 230lpm to empty a full tank?
Less than 6 minutes
What is the capacity of the foam tank?
80 litres
What foam is used, and what percentage solution does it require for flammable liquids?
Auxquima, at 3%
What needs to be applied in order for the PTO to be engaged?
The handbrake must be applied, and the appliance in Neutral
How would you know if the green autofill valve marker is open?
If it is open, the yellow marker will be inline with the pipe.
If it is closed, the yellow marker will be at right angles to the pipe.
What button would you use to release the hydrant pressure?
HTT
Hydrant to tank
Why is there no emergency bypass lever on the mark 3 appliance?
The autofill valve is spring loaded. It will always return to the open position.
Which delivery outlets are hydraulically more efficient on the mark 3
Deliveries 1 and 2.
These (whenever possible) should be used during a water relay
When working in low pressure, in what increment will the fine adjuster allow the pump operator to adjust?
0.2 bar
When working in high pressure, in what increment will the fine adjuster allow the pump operator to adjust?
1 bar