Ventilation JPR Flashcards

1
Q

Step 1

A

Determine the location of the fire within the building and the direction of attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Step 2

A

PPV must always be a coordinated effort with fire attack and should be situated at the lowest point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Step 3

A

Ensure you have a fan in proper working condition (check at the apparatus)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Step 4

A

Place the fan 4-10 feet from door opening used for fire attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Step 5

A

Provide for an exhaust opening at or near the fire before the fan is started

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Step 6

A

Ensure the exhaust opening must exceed the intake to the fire compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Step 7

A

Check the integrity of the building and ensure that no interior openings that could push combustion products into unwanted areas.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Step 8

A

When directed to do so, start the fan and check the cone of air on the door to ensure a complete seal by pulling back the back cuff of your glove, feeling around the door for air currents. Face shield should be down to prevent debris from being blown into your eyes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Step 9

A

If unable to get a proper seal, use of more than 1 fan or cover the door with plywood or salvage to reduce the size.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Step 10

A

Monitor operations to ensure that any factors that could hamper the effectiveness of the PPV are considered. Factors such as building integrity, opening and closing of doors, natural wind currents, placement of fire streams and obstruction of air flow.