Ventilation Flashcards

Reason for ventilation ,requirements for air vents,calculation of ventilator size.

1
Q

When an air vent is installed on the inside wall of a property, the vent must be sited

A

Not more than 450mm from the floor level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The ventilation requirement for open flued Appliances is dependent upon?

A

Heat input

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What action should the gas operative take if an air vent ,of adequate size but fitted with a fly screen,is encountered?

A

With the users permission remove the fly screen.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

An open flued combination boiler with hot water input of 36kw(net) and heat input of 21kw(net) is fitted within a kitchen measuring 2.5m by 2.2m by 1.8m.what is the free area required?

A

145cm squared

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A tumble dryer with an input of 5kw(net) is fitted in the kitchen in question before.An openable window is needed, but what is the additional vent free area required?

A

100cmsquared

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If both the Appliances mentioned in question 4 and 5 were fitted in the kitchen ,what is the vent free area,in addition to the openable window ,required?

A

145 cm squared

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A room sealed boiler with range rated burner from 16kw to 21 kw (net) is fitted in a compartment and set at 18.5 kw (net).what are the required vents direct out side?

A

105cm squared both the top and bottom.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A room sealed combination boiler with hot water input of 33kw (gross) and heating input of 25kw(gross) is fitted in a kitchen measuring 2.5m by 2.2m by 1.8m.what is the vent free area required

A

No vent required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A gas fire and back boiler of inputs 7kw (gross) and 16kw(gross) respectively recently been fitted in a bedsitting room. What is the ventilation required?

A

Installation not allowed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The purpose of a top vent installed with in a compartment is to

A

Remove warm air for cooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

An open flued boiler with input if 21.8 kw is fitted in compartment and vented to a room .what are the ventilation requirements?

A

Compartment………
Top vent- 218cm squared
Bottom vent- 436 cm squared

Room vent…………..
74 cm squared.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the Causes of incomplete combustion?

A

Insufficient air for combustion, overgassing, undergassing, flame impingement and chilling, vitiation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are the visual signs of increasing combustion ?

A

Staining around the Appliances ,signs of sooting with in the Appliances, yellow flames with in the Appliances.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Carbon monoxide detectors should be installed?

A

Minimum 150mm below ceilings,
At least 300mm away from wall
Between 1.8m and 3m from fire source.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly