Vacant Buildings Flashcards

0
Q

ALL vacant buildings must be identified and marked

A

The same way

Box with an X in it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

The IC may implement an interior attack after a risk assessment has been performed based on the following factors

A
  • Current structural stability of the building
  • Any KNOWN life hazards
  • Size and location of fire
  • Verification of safe access to the fire
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What color is the paint

A

Lime Yellow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What size is the vacant building marking

A

18 X 18

2 inch wide lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Can vacant buildings be marked by other than the Administrative unit

A

Yes
The officer supervising the marking must notify the Administrative Company at the 1st opportunity that the building has been marked

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Can vacant buildings be marked during BISP

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fires in vapors of diesel fuel develop

A

Slowly at the start but progress rapidly as vapor production intensifies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The 1st arriving BC shall establish the ICP

A
  • Across the street

* Outside a possible collapse zone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If the IC cannot get a clear situation report from units on the scene, he may have to

A

Change tactics to a defensive or exterior operation until proper size up can be made

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Prover size up for vacant building fires

A
  • Life
  • Exposures
  • Confinement
  • Extinguishment
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

At vacant building fires the 1st to arrive ____ shall assume the position of IC and establish the ICP across the street from the fire building outside the collapse zone

A

BC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Determination of the method of attack, exterior or interior, may have to be made by the 1st arriving officer. General consideration to consider

A
  • Any known or indicated presence of life in the building
  • Location and the extent of the fire
  • Exposure problems
  • Number of units responding to initial alarm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fires in vapors of diesel fuel develop _____ at the start, but progress ________ as vapor product intensifies. Heat developed will be for a longer duration than that involving gasoline.

A

Slowly

Rapidly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is a disadvantage of ILP

A

It MAY not be possible to attain full pump capacity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In industrial areas many TL’s carry on the side of the apparatus ______ lengths of their own 3 1/2 hose

A

4 to 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When putting a TL in a vacant lot who surveys the lot for stability

A

Officer

Chauffeur