utility drawing rules Flashcards
1
Q
what pipes connect to every house, and where do they terminate
A
strom, sanitary, sewer
the responsability of a muni contractor terminated at front prop line
2
Q
where to connect storm and sanitary sewer lines
A
low side of a lot.
3
Q
storm and sanitary sewer systems
A
- they are gravity sewer systems, and flow to the city mains by gravity.
- city mains located at lower part of subdiv.
- They start at the highest pt.
- Storm and sewer pipes cannot be curved, and must use straight sections between manholes of max length 150m
- max length between manholes is always 150 m
manholes required when:
- change in dir’n
- two lines intersect
- they must have min 1m clearance from eachother, CL to CL
4
Q
gas, power, telephone
A
shallow utilies which are located outside pavement
5
Q
water system
A
- pressure system, up or downhill
- no manholes, fitting used for
- beginning and end of water main
- change in dir’n
- two seperate lines intersect
- curves are allowed if pipe R is greater than 60m
- water main must be looped if it is greater than 150m in length
- dead end main shorter than 150m allowed
- must be at least 3m from storm and sanitary, CL to CL
6
Q
easement
A
- a strip of land within a private lot for the purpose of operating the water and sewer systems
- city can access it whenever
- min 3m width, could be more when two pipes are side by side
- if water and san/storm (sewer) go thru, need min CL distances