Usually PVC used to protect in Underground Situations
Conduit
Device that allows Cable lines to Branch off the feeder
Tap
taps that deliver higher signal than Normal.. Usually in MDU situations
Hot Taps
Depth of a conduit
12”
Drop conduit at house
4`
Drop conduit at pole
8`
Riser
Protective Guard for Transitioning Cable
One call Program for detailed info on Utilities (call before you dig)
811
Code for Marking utilities
ANSI Cod Z 535.1 (ANSI American National Standards institute)
Color used for Proposed Excavation
White markings
Color used for Temp Utilities
Pink Markings
Color used for Electric power lines
Red Markings
Color used for Gas oil Petroleum
Yellow Markings
Color used for Potable water
Blue markings
Color used for Reclaimed water/ Irrigation
Purple Markings