Truck Company Operations Flashcards
According to
the National Fire Protection Association, a modern quint must have the following elements
-a fire pump with a capacity of at least 1,000 gpm;
a water tank that can hold at least 300 gal;
at least 40 cu ft of enclosed compartment storage;
a suction hose, including a minimum of 15 ft of soft suction hose or 20 ft of hard
suction hose for drafting water;
an aerial ladder or elevated platform with a permanent waterway;
85 ft or more of ground ladders, including at least two extension ladders, one straight
ladder equipped with roof hooks, and one attic ladder; and
A hose storage area with at least 30 cu ft of storage able to accommodate a fire hose
of 2 1/2 in. or larger, plus two areas, each a minimum of 3.5 cu ft, to accommodate 1
1/2-in. or larger preconnected fire hoselines.
SLICERS
Size up
Locate the fire
Identify the flow path
Cool from a safe distance
Extinguish fire
Rescue
Salvage
The most critical factor in positioning the truck involves?
Determining the intended target or task
The first due truck company should aim to position on?
Side alpha or the address side of the building
Second due truck company should aim to position?
On the opposite side of the building
If there is limited or restricted access to the sides of the structure, the truck company should?
Position at the best location available and communicate that position to command.
Driver should position the turntable?
In line with the target and in reach of multiple locations as possible
Operators and officers should make the decision of whether to _________in a rear-mounted aerial or _______ in a mid mount based on incident dynamics
Back in a rear-mounted; Nose
Positioning a turntable involves observing?
Smoke conditions and direction
Position turntable slightly?
Upwind
When there are multiple priorities, positioning should prioritize:
Life safety for civilians and firefighters
The driver and OIC should scan for obstructions that may interfere with?
Aerial ladder deployment
Horizontal distance between building and the turntable is?
Setback
The scrub aera is the portion of the building that can be?
reached by the tip of the aerial or the bucket of the tower
Positioning on the corner of the building allows for?
more scrub area