A hook should be removed from service if
The tip is bent or twisted
Determine the weight of a load consisting of 100 brass rods, 6 ft. long and 1.5 inches in diameter. (The weight per linear foot is 6.51 lb.)
3,906lbs
If a rope has a breaking strength of 25,000 lb and the design factor of the sling is 5, what is the maximum allowable load they can lift?
5,000lbs
A sling should not be attached to a load ____________ its center of gravity.
Below
Which type of hook has a wide, deep throat to fit the handles on castings?
Foundry hook
If a wire rope is classified as 6 x 37, the figure 37 means that
Each strand of the rope contains a nominal 37 wires
Which of these wire-rope end fittings is the most efficient (assuming all are prepared correctly)?
Speltered socket
The letters FC, as part of a wire rope designation, stand for
Fiber core
Extra improved plow steel always has which type of core?
IWRC Independent wire rope core
As a general rule, what are the minimum and maximum temperatures to which a wire rope sling maybe exposed and still maintain its strength?
-60/+400°F (-51/204°C)
Corrosion on a wire rope usually indicates severe environmental conditions or a lack of
Lubrication
Which of the following hitches cannot be made with a basic single-leg sling?
Basket
The length of wire rope between loops or end fittings of braided wire-rope slings should be a minimum of __________ times the diameter of the component wire rope
40
If an alloy steel chain sling has been subjected to temperatures over 1000° F (540° C)
It should be removed from service
You should recommend removing a metal mesh sling from service if
One welded joint at the edge of the sling is broken