Test Method C1064: Temp of Freshly Mixed Hydraulic Cement Concrete Flashcards
The sensor of the temperature measuring device shall be submerged a minimum of ___ inches into the freshly mixed concrete.
3 in.
The temp measuring device shall have a capacity of measuring temp or freshly mixed concrete to ___ degree F. It ranges from ___ to ___ degrees F.
1 degree F.
30 - 120 degrees F
The temp measuring device shall be calibrated ______, or whenever there is a question of _____.
annually, accuracy
The temp of concrete may be measured in a wheelbarrow. T/F
True
The temp of concrete may be measured in a wall form. T/F
True
A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature. T/F
False
What must be done to the sample container prior to sampling the concrete?
Dampen (with water)
What must be done to the concrete surrounding the temp measuring device after the device is submerged in the fresh concrete?
Gently press the concrete around the temperature measuring device at the surface of the concrete.
How long must the temperature measuring device remain in the freshly mixed concrete?
At least 2 minutes, but no more than 5.
After the temp of the concrete is read, what is required?
Reporting of temperature
The temp of concrete is reported to the nearest ___ degrees F.
1 degree
According to ASTM C1064, what is one reason to take the temperature of concrete?
Verify conformance to a specified requirement for temperature of concrete.
A maximum temp of freshly mixed concrete is specified in ASTM C1064. T/F
False
The sample of concrete used for temp determination must be rodded 25 times. T/F
False