TB-69 Maxi-Force Air Bag System Flashcards
What is the dual “dead man” safety relief control valve set at?
Pre-set at the factory at 118 psi.
What are the components of the maxi force air bag system?
- One dual dead man safety relief and control valve
- One high pressure regulator
- Three in line safety relief valves
- Four air hoses: Red, yellow, green, blue
- Three air lifting bags: 2-22 ton, 1-12 ton
- One air supply adapter
- Cribbing
High pressure regulator should be adjusted to a presssure between _______to_______psi, to provide 118 psi working pressure at the dual safety relief and control valve.
125-135 psi
When attaching the SCBA bottle, the last ______ turn should be accomplished by turning both the threaded inlet fitting and regulator until hand tight.
1/4 turn
In line safety relief valves with relieve if the pressure exceeds ______psi.
135 psi
Each air hose has a working pressure of _____psi and is ______ft in length.
250 psi
16 ft
Air bags are constructed of _________.
neoprene rubber compounds encasing kevlar cords.
The adapter allows for us of an auxiliary air source such as _______ and _________. It also can be used to extend hose length (air chisel hose to air bag hose).
Apparatus on-board air system
Portable air compresser
The cribbing provided should be considered a minimum:
- 4”x6”x2’ (4)
- 24”24” plywood (2)
- Wedges (4)
Recommended that companies add additional cribbing to their inventory.
Where should the in line safety relief valve be placed?
At the dual safety relief and control valve.
Do not inflate the bag over _____ psi without a load.
30 psi
Rule of thumb is “_________________”.
Lift an inch, crib an inch.
In a two bag stacked lift, which bag is on the bottom?
Larger bag is on bottom.
Members in squatting position should keep weight on ___________ for a quick escape.
balls of feet
Never inflate air bags against objects hotter than _______ degrees F.
220 degrees F