When tying off the monitor, secure to an object capable of?
Withstanding 900 lbs/400 kg of force “warning”
Weight of portable monitor?
Upper assembly 17 lbs
Base 43.7 lbs
Total 61 lbs
Automatic drain closes when pressure exceeds what psi? And opens when it drops to that point.
5 Psi
Max flow is what gpm?
What if attached to 4” loaded hose?
800 gpm
Lafd can flow 1000 gpm if attached to loaded 4” loop of supply hose
How long is webbing?
8 ft w/carabiner included and each end has a loop.
What is the safety stop elevation?
35 degrees
How many spikes on legs/base?
5 or 6 tungsten carbide tipped spikes
When do we replace the spikes?
When spike tip diameter EXCEEDS 1/16” of an inch.
How much straight hose is needed behind base?
Minimum of 10 ft.
Site selection for monitor?
Flat, even surface within 8 ft of the 4” inch supply hose loop or sturdy object that can be used as an attachment point.
Where is ladder strap secured?
Ladder strap first female coupling alongside 4” inch hose 10 ft back from male coupling.
How do we lubricate for maintenance?
Worm gear lubrication, elevate nozzle to highest elevation and pump grease (medium viscosity automotive) into the fitting (zerk) in the worm gear housing until excess appears.
What is the friction loss for the portable monitor?
Pump at the following pressures to the shut off valve at the inlet of the portable monitor. SPRAY TIP (PSI) 350 GPM - 105 PSI 500 GPM - 115 PSI 750 GPM - 110 PSI 1000 GPM - 125 PSI Portable Monitor: Maximum of 1000 GPM
Maintenance?
The Crossfire monitor and its base require little maintenance. The unit should be kept clean and freeof dirt by flushing with water after each use. After each use, the unit should be inspected according
to the following guide. All controls should be checked for freedom of movement and condition. Any
inoperable or damaged part should be repaired or replaced immediately.