TB- 120: Ladder Pipe Operation Flashcards
When spotting for ladderpipe, apparatus should be jackknifed how?
60 degrees from inline, away from direction of
ladder extension
Ladder angle should be how many degrees? Not
exceeding?
75 degrees from horizontal, not exceeding 80
Ladder pipe ladder extension limits?
100 foot aerials = 80 ft
85 ft aerials = 65 ft
To stop uncontrolled movement of aerial ladder,
nozzlemen should?
Raise nozzle upward to change direction of
reaction
When ladder pipe is in operation, operator shall?
-Remain at controls at all times
-Be alert to slippage or drifting of ladder
-Shutdown and retract ladder if movement of
apparatus is necessary
-Have a member remain at the cluster
Load the ladder pipe hose when angle of ladder
has reached?
50 degrees
Seagrave ladder pipe flow?
800 gpm at 80 psi
Members are prohibited from using the 2” tip or flowing 1,000 GPM
on Seagrave aerial ladder trucks.
Ladder straps ____ be utilized to secure the Akron 1495 onto the ladder.
Should Not