Systems - Electrical Flashcards

1
Q

Electrical System Voltage

A

28v

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Electrical System Primary Components

A

(2) Starter-Generators (30v Starter / 28v Generator)
(3) 24v Lead Acid Batteries (BAT 1(2) 22ah, BAT 3 7ah)
(3) Static, single-phase Inverters (400hz, 115v AC)
(1) 26v Transformer (CC-50 and earlier)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Starter-Generators provide power to…

A

…Secondary Bus Bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Voltage Limits for Starting

A

minimum 23v maximum 29v

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Amperage before Second Engine Start

A

below 100amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Starter-Generator functions as Starter until

A

60% RPM

Automatically Disconnected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Starter-Generators may be brought online as Generators at

A

65% RPM

RESET then ON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Cross-Generator Start Engine RPM

A

80%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If a fault develops on the SEC BUS the Generators will…

A

…be automatically transferred and provide power to the ESS Bus Bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When can the Generators be transferred back to the SEC BUS

A
  • on the ground
  • after maintenance
  • utilizing the GEN to SEC BUS switches
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Each Generator Control Box protects against

A

overvoltage
reverse current flow
ground faults

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Each Generator Control Box serves to

A

equalize and regulate 28v DC

provide protections

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Each Generator Control Box can be tested to…

A

… simulate either –

    • overvoltage
    • ground fault

testing illuminates the GENERATOR warning light on the glareshield panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Batteries Provide Power to…

A

BAT 1 - ESS BUS
BAT 2 - START BUS
AUX BAT - PRIMARY BUS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

AUX BAT function during start cycle

A

to supply constant voltage to critical temperature indication and starting systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

AC Power Provided by:

A

3 static, single-phase, 400hz, inverters
– convert 28v DC to 115v AC
26v Transformer converts 115v AC to 26v AC

17
Q

No. 1 and No. 2 Inverters power

A

No. 1 and No. 2 Inverter Bus Bar, respectively

– powered by AUX BAT BUS (PRIMARY BUS BAR) –

18
Q

AUX Inverter

A

powered by ESS BUS

can power either No. 1 or No. 2 INV BUS

19
Q

48v Start Recommended

A
    • first start of the day

- - OAT below 5ºC