GENERATOR LEFT (RIGHT)
GEN not connected to SEC BUS
INVERTER NO 1 (NO 2)
voltage < 90 volts
– or –
output < 20 watts
FUEL LEVEL LEFT (RIGHT) TANK
collector tank below 120 lbs
Action:
Fuel Feeding Lever . . . CROSSFEED
Booster Pumps . . . ALL ON
FUEL SHUTOFF VALVE LEFT (RIGHT)
illuminated when electrical valve (operated by FUEL SWITCH) mounted on the aft of the fire-wall is closed
FUEL PRESSURE LEFT (RIGHT) ENGINE
fuel pressure decreasing below 3.5 psi
extinguishes above 7 psi
PITOT HEAT LEFT (RIGHT)
failure
WINDSHIELD LEFT (RIGHT)
temperature regulator failure
AIR INTAKE LEFT (RIGHT)
failed to open with ENGINE INTAKE switch ON
CHIP DETECTOR LEFT (RIGHT)
metal detected in gear case
OIL PRESSURE LEFT (RIGHT)
oil pressure < 40 psi
SRL & START LEFT (RIGHT)
illuminates when EGT not conditioned by computer
AUX INVERTER
voltage < 90 volts
– or –
output < 20 watts
UNSAFE DOOR
illuminates if any of the doors are not securely closed
OVERSPEED
200 knots detected by F/O pitot-static system
accompanied by aural cockpit horn