SUPERTECH TUTORIALS 1 & 2 & 3:-- 20 minute supertech exam--USE MY SUPERTECH!!! Flashcards
Supertech Tutorial 1 Introduction
THE SUPERTECH IS DESIGNED FOR ??
THE USER DETERMINES 2 MAIN FACTORS FOR ANY VIEW. THEY ARE??
***THE SUPERTECH IS NOT A ________TECHNIQUE GUIDE.
ANALOG XRAY SYSTEMS
1–SECONDS (TIME)
2–mAs (MILLIAMPS PER SECOND)
STATIC
Supertech Tutorial 1 Introduction
THE SUPERTECH USES A _______________ WHICH IS SPECIFIC FOR EACH XRAY SUITE.
ON THE FRONT OF THE SUPERTECH WE WILL ENTER 2 PARAMETERS. THEY ARE??
THE BLACK COLORED COLUMN IS FOR ________
THE RED COLORED COLUMN IS FOR __________
TCF (TOTAL CORRECTION FACTOR)
1–THICKNESS OF BODY MEASURED IN CM
2–TCF
ADULTS
CHILDREN —–UNDER—- 12 YEARS OLD
Supertech Tutorial 1 Introduction
THERE WILL BE THREE TCF’S IN EACH ROOM. THEY WILL BE FOR???
THE BACK OF THE SUPERTECH TAKES CARE OF WHAT 2 FEATURES?
1–REGULAR
2–EXTREMITY
3–CHEST
mAs
&
TIME OR SECONDS
Supertech Tutorial 1 Introduction
WHEN NOT CLEAR IN THE mAs…ALWAYS CHOOSE THE HIGHER NUMBER!!!
ALWAYS I SAID!!
Supertech Tutorial 2 Modifying the TCF
ON THE FRONT RIGHT SIDE WE WILL NOTICE IT SAY
“CORRECTION FACTORS”
THERE ARE 4 SEPERATE REGIONS
WHAT ARE THEY?
1–SID
2–GRID
3–MISC
4–TO CONVERT 50 mA COLUMN
Supertech Tutorial 2 Modifying the TCF
SID = SOURCE TO IMAGE DISTANCE
AKA ________ ___________ ____________
GRAB YOUR SUPERTECH!!
FIRST REGION IS LABELED:
———-SID (FFD)——————————
***CASE SCENERIO: PATIENT NEEDS AN AP-LOWER CERVICAL DONE AT 40 FFD SEE?
1–BUT YOUR OFFICE CAN ONLY SHOOT AT 72 FFD SEE?
2—YOU KNOW THE TCP AT YOUR OFFICE IS = -1 TCP
3….FIND THE COLUMN THAT HAS “FROM” 40” AND “TO” 72” FFD
4…..IT SAYS +3.5 SEE?
5—-SO….+3.5 TCP +( -1 TCP) = 2.5 TCP
6—PLUG IN 7O KVP FOR CERVICAL/ 13 CM ADULT CERIVAL/TCP = +2.5 AND YOU WILL GET YOUR “NEW”
___ mAs
“FOCAL FILM DISTANCE”
= FFD!!!
50 mAs
Supertech Tutorial 2 Modifying the TCF
SECOND REGION IS LABELED:
————-GRIDS—————
= MOST COMMONLY USE TO CHANGE FROM A ________ TO A _____________ TECHNIQUE. OR VICE-VERSA!!
***ON OUR SUPERTECH BOTH ___________ AND ___________ HAVE THIS OPTION BUILT IN ALREADY.
**CASE: PATIENT NEEDS TO GET XRAY OF LOWER BACK. HE CANNOT STAND AND YOU DO NOT HAVE A TABLE WITH A GRID LIKE A LOSER! WHAT TO DO?? USE A NON-BUCKY TECHNIQUE AND LAY THE BIG PUSSY DOWN RIGHT!?? THE PATIENT MEASURES AT 27CM AT THE LUMBAR AND A TCF OF -4 IS YOUR OFFICE NUMBER FOR "REGULAR CASSETTES" SEE? WHAT IS THE mAs FOR P TO A LUMBAR SPINE??? 1---GO TO GRIDS SEE? 2--SAY YOUR OFFICE HAS A 10:1 RATIO SEE? 3--"NON" SAYS -3.5 TCP SEE? 4--SO -4 + (-3.5) IS A NEW -7.5 TCP SEE? 5--PLUG IN 27CM AND -7.5 SEE? 6--WITH A KVP OF 80KVP YOU SHOULD GET \_\_\_\_\_\_\_\_mAs SEE??
BUCKY
NON-BUCKY
CHEST AND EXTREMITIES
15 mAs
Supertech Tutorial 2 Modifying the TCF
THIRD REGION IS LABELED:
———–MISC—————-
NAME 4 COMMON PATIENT VARIABLES!!
**CASE: BODYBUILDER WITH MID-BACK PAIN 1--LATERAL THORACIC IS 42 CM 2--YOUR OFFICE TCF IS -6 FOR REGULAR CASSETTES 3--YOU LOOK WHERE IT SAYS "MUSCULAR" 4--IT SAYS +1 RIGHT? 5--ADD -6 + (+1) AND YOU GET -5 TCF 6--SO 42CM WITH A -5 TCF...AND...KNOWING YOUR KVP IS 80 7--FLIP THE BITCH AND YOU GET\_\_\_\_\_\_\_\_
1–MUSCULAR
2–BIG BONED
3–FAT-ASS (OBESE)
4–OSTEOPENIC
75 mAs YO!!
Supertech Tutorial 2 Modifying the TCF
FOURTH REGION IS LABELED:
—–CONVERT 50 MA COLUMN
WHEW…..WHO GIVES A SHIT!! NOT IN THIS CLASS!!
Supertech Tutorial 3 Time and Working Backwards
TWO REASONS TO USE THIS SYSTEM ARE?
1–A KID OR ELDERLY CANNOT FUCKING SIT STILL!!
2–SOME MACHINES ONLY ALLOW TO MA AND TIME TO BE ENTERED SEPERATELY.
–AS OPPOSED TO mAs LIKE A REAL XRAY MACHINE!
Supertech Tutorial 3 Time and Working Backwards
CASE: 1---AP-LOWER CERVICAL IS 12CM 2--TCF FOR A REGULAR CASSETTE IS +2.5 3--RECOMMENDED IS 200 FOR APLC SO... 4--FIND 200 MA ON THE BACK 5--GO DOWN TO THE KVP FOR APLC WHICH = 70 6----YOU SHOULD GET\_\_\_\_\_\_\_\_\_ OR \_\_\_\_\_\_\_\_
ANSWER IN THIS CASE = 1/4 OR .25 SECONDS
SEE SLIDES 7–8–9
Supertech Tutorial 3 Time and Working Backwards
SEE SLIDE 10—>26 WITH YOUR SUPERTECH
EASIER THIS WAY TO UNDERSTAND AND FOLLOW ALONG WITH THE POWERPOINTS.
FUCK!