The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of what into the freshly mixed concrete?
3” inches
The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to what degree throught a range of what and what?
1°F, 30° to 120°
The temperature measuring device shall be verified what, or whenever there is a question of what?
Annual, accuracy
The temperature of concrete may be measured in a wheelbarrow. True or false?
True
The temperature of concrete may be measured in a wall form. True or false?
True
A composite sample of concrete is required is required even if the only purpose for obtaining the samples is to determine temperature. True or false?
False
What must be done to the sample container prior to sampling the concrete?
Damping
What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete?
Slightly press around surface
How long must the temperature measuring device remain in the freshly mixed concrete?
Minimum 2 minutes, Max 5 minutes
After the temperature of the concrete is read, what is then required?
Record it
The temperature of the concrete is reported to the nearest what?
1゚F
According to the test method C1064/C1064M, what is one reason to take the temperature of concrete?
To verify conformance to specifications
A maximum temperature of freshly mixed concrete a specified in test method C1064/C1064M. True or false?