studies to know for exam Flashcards
wilson and majnard
they cautioned against violating BIOLOGICAL WIDTH - cautioned against extending restorations so far subgingivally that the attachment complex is damaged.
stated that “some distance of unprepared tooth structure should remain between the finished line and junctional epithelium and this distance should ideally be 0.5mm”
stated that “some distance of unprepared tooth structure should remain between the finished line and junctional epithelium and this distance should ideally be 0.5mm”
wilson and majnard
richter
WHEN THE CROWN MARGINS ARE WELL FITTED AND WELL CONTOURED
- supra gingival margin vs sub gingival margin ; there is NO DIFFERENCE IN
- the health of the gingiva
- the depth of the sulcus
- the gingival contour
- in plaque accumulation
annerstad and norlander
dentists on average have a taper from 14.3 to 22.1
parker, maxwell, woosley and matich
recors resistance with regard to convergance indicated
- different OC dimensions with different TOC’s
parker, maxwell, woosley and matich - details
3mm is minimal OC dimension for premolars and anterior teeth that are prepared within the 10-20 degree TOC range
MOLARS = 4mm with greater convergence of the anterior and pre-molars
parker, malone III and trier
evaluated resistance of prep
90 incisors = 96% had reitance
25 canine = 92 % had resistance
72 pre-molars = 81% resistance
107 molars = 46% resistance
***100% OF PREPS WITH BUCCAL OR LINGUAL GROOVES HAS RESITANCE FORM TO MESIAL DISTAL DISLODGMENT
100% OF PREPS WITH MESIAL OR DISTAL GROOVES HAD RESISTANCE FORM TO BUCCAL AND LINGUAL DISLODGMENT
pascoe
made crowns and cemented them and checked thicness of cement line
crowns cemented to shoulder finish line fit bettern than the crowns that are fitted to shoulder with bevel
NO EVIDENCE THAT THE BEVEL WILL IMPROVE THE MARGINAL SEAL
checkbite needed in order to set protrusive?
set condylar inclincation we need ___ postional checkbite?
PROTRUSIVE CHECKBITE
- END POINT OF PROTRUSIVE TO SET ANGLE
laufer et al
need a 2mm sulcus – need enough width of sulcus for the impression material
affect of marginal thickness on the distortion of different impression materials
details on pick up impression
will be a solid cast - no removable dies
will fit a soldered casting
will show the relation of the soft tissue to the casting for esthetic purposes as well as for the design of the pontic
must be correctly mounted for porcelain application
removable dies in pick up impressions?
NO
pick up impressions - what jerry said
great tools
impression of 8 and got margin but not adjacent tooth
so make substructure and then transfer impression
capture #9 in a new impression
same with frameworks that were cut – ONLY PFM’S
pick ups with zirconia
NO
emax must be
crystallized - not polishing it