What are the problems when a boiler operates at less than design pressure?
Greater specific volume
Decreased separation area
Lower quality of steam
Name 4 drip station locations on steam lines
Elevation changes
Changes of directions
End of mains
In front of control valves
What is the problem with under sizing steam pipes?
Lower pressure to steam users
Not enough volume steam
Water hammer and erosion
Why is it important to vent air from steam piping systems?
If not it can:
Lower steam Temperature
Prolong start up
Increase corrosion
Name 3 types of pressure reducing valves
Direct acting
Pilot operating
Pneumatic or electric
Name 3 types of steam traps
Mechanical
Thermostatic
Kinetic energy
What is the purpose of a steam trap?
To remove condensate within the system
What are the most common steam traps in breweries?
Mechanical (float with thermostatic valve)
Give 4 reasons for returning steam condensate
Water already treated
Temperature still warm to hot
High cost of condensate disposal avoided
Water charges are lowered (not using a ton of fresh water)
What is stall in a steam supplied heat exchanger?
When necessary pressure differential across a drainage device becomes negative, causing condensate to pool inside boiler