STEAM/HYDRONICS Flashcards

1
Q

the amount of heat released by a defined measurable amount of fuel during combustion process is a definition of:

A

Calorific value

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The impusle of heated gas to rise in a vertical passage as in a chimney, small enclosure or stairwell is a definition of

A

stack vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A device installed in the piping that opens a circuit if no flow is present is a definition of an

A

flow switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what is a example of a limit control

A

fan switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

the energy to raise temperature without changing physical state is known as

A

sensible heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

the energy required to change physical state without changing temperature is

A

latent heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

transfer heat through liquid or gas is known as

A

convection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Flue gas will condense when it is cooled to its dew point temperature. this condensate is considered to be

a, potable
b, nuetral
c, alkali
d, acidic

A

acidic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What will be found on a heating boiler that is approved to the A.S.M.E standard?

A

H

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what device compensates for the normal expansion and contraction of the water in a hot water boiler

A

diaphragm tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

what mandatory device is required by A.S.M.E n a low mas boiler over 400,000 btu

A

flow switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what can cause coil damage in a low mass boiler

A

scale build up in the heat exchanger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

where is the best location of a circulator

A

downstream from the compression tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

what is the purpose of a flow control valve

A

to prevent the pump from deheading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

why is important to remove gases from hot water heating system

A

to prevent air binding in the system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

most gauges on a boiler have an accuracy of %

A

1 to 1.5 %

17
Q

purpose of a balancing valve

A

to adjust flow rates throughout the system

18
Q

what is the name of the piping system in which the first heat transfer unit supplied is also the first returned

A

two pipe direct return

19
Q

what causes convection currents

A

different air densities

20
Q

what method of a heat transfer is utilized by a plate heat exchanger

A

conduction

21
Q

What is the minimum amount of lightweight concrete required over the tubing when installing a radiant panel over wood surface

A

3/4

22
Q

Radiant tubing installed below wooden floors requires special components to aid in the lateral migration of hat. what are these components called

A

transfers plates

23
Q

what effect would raising a fin vector above recommended installation height have on the heat output

A

heat output would be reduced

24
Q

how does a forced air heating system heat a room or space

A

from the ceiling down to the floor

25
Q

what is the manufacture recommended length of pex tubing

A

300 ft

26
Q

radiant floor heating typically operates at water temperature

A

140 degrees f