- Demagnetization, ASTM E709-95 recommends a coil of ampere-turns:
(a) 1000 to 3000
(b) 3000 to 5000
(c) 5000 to 10000
(d) 10000 to 15000
(c) 5000 to 10000
- According to ASTM E709-95 when dry particles are used magnetic particle testing
shall not be performed on the surface of parts whose temperature exceeds:
(a) 57ºC
(b) 79ºC
(c) 158ºC
(d) 136ºC
(a) 57ºC
- According to ASTM E709-95 in using prod technique, prod spacing shall not exceed:
(a) 50 mm
(b) 100 mm
(c) 150 mm
(d) 200 mm
(d) 200 mm
According to ASTM E709-95, the UV intensity shall not be less than:
(a) 600 μW/cm2
(b) 700 μW/cm2
(c) 800 μW/cm2
(d) 900 μW/cm2
(c) 800 μW/cm2
- According to ASTM E709-95 in using prod technique on a 50 mm thickness plate
with a prod spacing of 101 mm (4 inches), current shall be selected in the following
range:
(a) 300-450 A
(b) 400-500 A
(c) 500-625 A
(d) 550-700 A
(a) 300-450 A
- According to ASMT E709-95 alternating current electromagnetic yokes should give a
lifting force of at least:
(a) 1.5 kg
(b) 2.5 kg
(c) 3.5 kg
(d) 4.5 kg
(d) 4.5 kg
According to ASTM E709-95 direct current electromagnetic yokes should have a
lifting force of at least:
(a) 15 kg
(b) 16 kg
(c) 17 kg
(d) 18 kg
(d) 18 kg
- According to ASTM E709-95 the UV light shall be centred on (1 Å = 10-10m):
(a) 3000 Å
(b) 3250 Å
(c) 3400 Å
(d) 3650 Å
(d) 3650 Å
- According to ASTM E709-95 when fluorescent particles are used, the UV light
intensity shall be above:
(a) 700 μW/cm2
(b) 800 μW/cm2
(c) 900 μW/cm2
(d) 1000 μW/cm2
(c) 900 μW/cm2
- According to ASTM E709-95 when fluorescent particles are used, the bulb shall be
warmed up prior to use for at least:
(a) 1 min
(b) 2 min
(c) 3 min
(d) 4 min
(e) 5 min
(e) 5 min
- According to ASTM E709-95 with prod technique, the prods shall be tipped if the
open circuit voltage is over:
(a) 10 V
(b) 15 V
(c) 20 V
(d) 25 V
(d) 25 V
- According to ASME Section VIII, a linear indication is defined as an indication in
which the length is equal to or greater than the width by a factor of:
(a) 1
(b) 2
(c) 3
(d) 4
(c) 3
- According to ASTM E709-95 the viscosity limit (measured in centi Stokes) of the wet
medium (conditioned water) should not exceed:
(a) 1 cSt
(b) 3 cSt
(c) 6 cSt
(d) 4 cSt
(c) 6 cSt
- According to ASTM E709-95 when applying fluorescent magnetic particles technique,
the operator shall be in darkness area at least …………… prior to examination:
(a) 2 min
(b) 3 min
(c) 4 min
(d) 5 min
(b) 3 min
- According to ASTM E709-95 the alkalinity of conditioned water shall not exceed:
(a) 10.0 pH
(b) 10.5 pH
(c) 11.0 pH
(d) 11.5 pH
(b) 10.5 pH
- According to ASTM E709-95, with wet continuous magnetization technique, the
duration of magnetization current is of the order of:
(a) 0.5 sec
(b) 1.0 sec
(c) 1.5 sec
(d) 2.0 sec
(a) 0.5 sec
According to ASTM E709-95 in using prods having a spacing of 19 mm (3/4 inches)
and above, the magnetizing current shall be:
(a) From 90 to 110 A/25 mm (1 inch)
(b) From 100 to 125 A/25 mm (1 inch)
(c) From 90 to 120 A/ 25 mm (1 inch)
(d) From 100 to 200 A/25 mm (1 inch)
(b) From 100 to 125 A/25 mm (1 inch)
- According to ASTM E709-95 powder shall be applied upon the part to be tested in
such a manner that:
(a) A light uniform coating is formed
(b) In excess coating
(c) All of the above
(d) None of the above
(a) A light uniform coating is formed
- According to ASTM E709-95 before turning off current and examination, dry powder
in excess shall be:
(a) Removed by a dry-air current
(b) Kept in place
(c) All of the above
(d) None of the above
(d) None of the above
- According to ASTM E709-95 demagnetization can be performed by:
(a) Decreasing alternating current
(b) Reversing direct current
(c) All of the above
(d) None of the above
(c) All of the above
- According to ASTM E709-95, Table 3., alternating current electromagnetic yokes
must have a lifting force of at least:
(a) 3.0 kg (7 lb)
(b) 3.5 kg (8 lb)
(c) 4.0 kg (9 lb)
(d) 4.5 kg (10 lb)
(d) 4.5 kg (10 lb)
- According to ASTM E709-95, Table 3., direct current electromagnetic yokes must
have a lifting force of at least:
(a) 15 kg (33 lb)
(b) 16 kg (36 lb)
(c) 17 kg (38 lb)
(d) 18 kg (40 lb)
(d) 18 kg (40 lb)
According to API, the acceptable particle concentration of wet particle solution for
fluorescent particles is:
(a) 0.1 to 0.4 mL by volume
(b) 0.1 to 0.5 mL by volume
(c) 0.1 to 0.6 mL by volume
(d) 0.1 to 0.7 mL by volume
(a) 0.1 to 0.4 mL by volume
- According to API, the particle concentration of wet particle solution must be checked:
(a) Prior to each shift
(b) Only after each shift
(c) Only each week
(d) Only each two weeks
(a) Prior to each shift
- According to ASTM E709-95 and API, the UV intensity measured at a minimum of
38 cm (15 inches) at least shall not be less than:
(a) 700 μW/cm2
(b) 800 μW/cm2
(c) 900 μW/cm2
(d) 1000 μW/cm2
(d) 1000 μW/cm2
- According to ASTME 709-95 and API, in order to eliminate all contaminants, an
appropriate cleaning shall be performed on all the surfaces to be examined and on a
minimum of adjacent material:
(a) 25.4 mm (1 inch)
(b) 31.7 mm (5/4 inches)
(c) 38.1 mm (1.5 inches)
(d) 44.5 mm (7/4 inches)
(a) 25.4 mm (1 inch)
- According to ASTM E709-95 and API, the temperature of the dry particles can be
usable up to:
(a) 38ºC
(b) 2000ºC
(c) 49ºC
(d) 315ºC
(d) 315ºC
- According to ASTM E709-95 and API, the thickness of non conductive coatings will
not exceed:
(a) 1-10 mm
(b) 2-5 mm
(c) 0.02-0.05 mm
(d) 0.001-0.004 mm
(c) 0.02-0.05 mm
- According to ASTM E709-95 and API, relevant indications are produced by:
(a) Greasy surfaces
(b) Excessive background
(c) Leakage fields
(d) Rotating Eddy currents
(c) Leakage fields
- According to AST M E709-95 and API, after removing magnetization of parts after
examination, the residual magnetism shall not exceed (1 gauss = 0.0001 tesla):
(a) 3 × 10-4T (3 gauss)
(b) 4 × 10-4T (4 gauss)
(c) 6 × 10-4T (6 gauss)
(d) 8 × 10-4T (8 gauss)
(a) 3 × 10-4T (3 gauss)
- According to ASTM E709-95 and API, when fluorescent particles are used, the UV
bulb shall warm up prior to use for at least:
(a) 1 minute
(b) 2 minutes
(c) 3 minutes
(d) 5 minutes
(d) 5 minutes
- According to ASTM E709-95 and API, a linear indication is defined as an indication
in which the length is equal to or greater than the width by a factor of:
(a) 1
(b) 2
(c) 3
(d) 4
(c) 3
- According to API, a non- relevant indication is defined as an indication which in the
major dimension is equal to, or less than:
(a) 1.59 mm (1/16 inches)
(b) 2.4 mm (3/32 inches)
(c) 3.2 mm (1/18 inches)
(d) 4 mm (5/32 inches)
(a) 1.59 mm (1/16 inches)
- According to ASME Section V, with fluorescent magnetic particles technique, the
operator shall be in darkness area at least ……………. prior to examination:
(a) 2 min
(b) 3 min
(c) 4 min
(d) 5 min
(b) 3 min
- According to ASME Section VIII Div 1, Appendix 6, on pressure containing welds
whose depth is greater than 15.8 mm (5/8 inches), which of the following indications
is unacceptable:
(a) Rounded relevant indication with a major dimension less than 3.2 mm (1/8
inches)
(b) Rounded relevant indication with a major dimension less than 3.2 mm (1/8
inches)
(c) Rounded relevant indication with a major dimension greater than 4.8 mm (3/16
inches)
(d) None of the above
(c) Rounded relevant indication with a major dimension greater than 4.8 mm (3/16
inches)