SOP A1 - High Rise Flashcards
A1 - what is the PDA for a high rise
3 nearest pumps, Aerial appliance and FDO
A1 - What is a medium rise?
A building with 5-7 floors
A1 - What is a high rise?
A building with 8 floors or more
A1 - At what height do dry risers need to be fitted?
18m up to 60m
A1 - At what height do wet risers need to be fitted?
60m or 50m in new builds
A1 - what are the typical sectors at a high rise fire
Lobby sector, bridgehead, fire sector and search sector
A1 - when charging a wet riser what pressure does the first appliance deliver?
7 bar
A1 - when charging a wet riser what pressure does the second appliance deliver?
10 bar
A1 - What would you expect a lift to do when the “fireman’s switch” is operated?
Automatically return to lobby - to be controlled from within the car
A1 - Which stations have high rise packs?
09, 10 and 15
A1 - What are the initial actions on arrival at a high rise incident?
Seek additional info (location may not be visible or scale unknown)
DRA
Contact site manager for info (if available)
Set up cordons
A1 - What are the objectives of the first appliance?
Information gathering
Securing water supply (check valves if poss)
Anti-ventilate if poss
Check for automatic smoke control or ventilation
Consider twin lengths standpipe - appliance - riser
Prep equipment for the lobby sector
Set up lobby sector
Supply equipment to the fire sector
A1 - What firefighting equipment is taken to bridgehead?
1 x 70mm hose (short length) 3 x 45mm hose (cleveland roll) 1 x branch Dividing breech appropriate hand held extinguishers TIC
A1 - What gain access equipment should be taken to the bridgehead?
Sledge
Hooligan bar
Bolt croppers
Keys
A1 - What BA and comms equipment should be taken up to the bridgehead?
ECB
2 x Sets
Fireground radios