SOP 215 Emergency Removal Of Passengers From Stalled Elevators Flashcards
How long is reasonable amount of time to wait for elevator mechanic
20-30 minutes
It may be necessary to activate ** to transfer emergency power to elevators
Recall procedures
What is the only directive given to passengers prior to shutting down power
Both apply force in closing direction to attempt to close the safety circuit and reenergize the car
If unable to lockout the elevator
1 member must stay in machine room with radio
The board of elevator regulations require that an elevator equipped with a hoistway door unlocking device
The device must be secured in the building and readily available to FD
Once power is cut just the occupant is instructed to
Try to roll open the door
If the elevator is within *** feet, then door is forced and occupants can be removed without response of district chief
3 feet
Use of side panels are
No longer permitted
Forcible entry should be attempted by these 3 means in this order
Mini lifting bag
Rabbit tool
Halligan
Basic tactic for elevator accidents involving injury
Stabilize car, then move enough to stabilize victim
Members are/are not allowed to restore power to elevator involved in injury
Are not
A DFS elevator emergency operation report FEO 3502 whenever a FEO switch
Malfunctions or is damaged
A DFS Elevator Response Form E52A must be filled out whenever
Person is injured, extricated, or power terminated to elevator or escalator
IC must document in NFIRS that all documentation is complete and
Emailed when necessary and FAO notified
An elevator car must be within ** inches of the floor to be within the landing zone
18 inches