sog 3 parking structure Flashcards
what are the safety considerations for parking structures
firefighter safety, life safety, structural stability, securing utilities
what accountability level is the minimum for parking structures
level 2
apparatus placement for parking structures
placement will be dependent on fire locations and building access
what are the forcible entry issues that present unique obstacles
locked roll down gates, stairwell doors, or drop arms
what are the ventilation issues with parking structure
low ceilings may cause a bank down effect with the smoke
what is paramount and should be identified early in a parking structure incident
fdc and hydrant locations
what are some of the issues associated with parking structures
lack of visibility, moving vehicles, traffic control, low ceilings, limited entry/egress., auto extension, fuel runoff, exposures, structural stability
what type of attack is to be considered in parking structures
use of fixed or improvised standpipes systems, extended hose lays and the use of foam may be required
what should be done with stairwells and elevators during parking structure fires
ensure an evacuation stairwell, evacuate the entire building, clear the elevators and stairwells of occupants.