Smoke/Fire Flashcards

1
Q

What Extinguishing Agent is used in the Fire Bottles?

A

HALON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Where are the Engine Fire Detection sensing elements located?

A
  • Fixed Cowl.
  • Accessory Gearbox;
  • Engine Core;
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What must happen to activate the Fire Warning System?

A
  • Both paired loops in a section must sense heat;
  • If 1 loop is inoperative, the remainder loop will activate the FIRE Warning.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How is the Fire Detection/Suppression for the Baggage Compartment provided?

A
  • Smoke Detectors;
  • BTL 1 can be discharged into the baggage compartment.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During an Engine Fire, what 5 indications come on?

A
    1. The respective L/R ENG FIRE PBA illuminates;
    1. Red L/R ENG FIRE CAS message displays;
    1. FIRE icon in the N1 gauge;
    1. Aural Warning voice message, Left (Right) Engine Fire;
    1. Master Warning PBA flashes Red on the glareshield.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What 6 events occur when the L/R ENG FIRE PBA is pressed?

A
    1. Firewall Fuel Shutoff Valve closes;
    1. Hydraulic SOV closes;
    1. Engine PRSOV closes;
    1. Generator is taken offline;
    1. Ignition is disabled;
    1. BTL 1 & BTL 2 PBAs illuminate green AVAIL to indicate Armed.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Does pressing the ENG FIRE PBA command an immediate Engine Shutdown?

A
  • NO. The FIRE PBA closes the Fuel feed SOV at the firewall. Engine will run a few sec to empty the line.
  • Immediate Shutdown is via the ENGINE RUN switch per the checklist
  • Note: The ENGINE RUN switch closes the HPSOV in the fuel metering unit.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What 5 events occur when APU FIRE PBA is pressed?

A
    1. APU Firewall Fuel SOV closes;
    1. APU Fuel Control Unit shuts off the fuel;
    1. APU Bleed Control Valve (BCV) is closed;
    1. APU Generator is taken offline;
    1. BTL 2 PBA illuminates green AVAIL to indicate Armed.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If an APU Fire is detected on the Ground, what’s the automatic shutdown/extinguishing sequence events?

A
    1. APU FIRE Warning Horn sounds outside the airplane;
    1. APU BCV closes
    1. FIDEEX triggers APU Shutdown;
    1. Within 10 seconds of detection, BTL 2 discharges.
      NOTE: The APU may be left unattended.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly