The stem of the thermometer is submerged a minimum of ____ into freshly mixed concrete
3 inches
The thermometer shall be capable of accurately measuring the temp of freshly mixed concrete to _______ throughout the range of_________
1 deg F / .5 deg C - - - - - 30-120 deg F
The thermometer shall be verified within ________
within 1 year of its current use
True or False: Temp may be measured in a wheelbarrow
true
true or false: the temp of concrete may be measured in a wall form
true
true of false: A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature.
false
What must be done to sample container prior to sampling the concrete ?
dampen surface
What must be done to the concrete surrounding the thermometer after the device is submerged in fresh concrete
push concrete around the stem to ensure it is in full contact with the concrete
How long must the thermometer remain in the freshly mixed concrete?
2-5 min
After the temp of the concrete is read, what is then required?
record the temp
the temp of concrete is recorded to the nearest _____
1 degree F or 0.5 C
true or false: There is a specified max temp of freshly mixed concrete
false
true or false: the sample of concrete used for temperature determination must be rodded 25 times.
false