SCBA Written Test Flashcards
Will the SCBA provide protection against all toxins and poisons?
No protection against gases, mists or vapors which are skin absorptive.
Which SCBA does the LAFD currently use?
Honeywell Titan
NFPA 1981
Standard on open circuit SCBA
NFPA 1982
Standard on PASS
NFPA 1404
Standard for fire service respiratory protection program
Pull strength
1000lbs
of gear straps and rating
4 gear straps with 100lbs rating
Batteries for SCBA
4 'C' batteries Duracell MN1400 Duracell PC1400 Energizer E93 Energizer EN93
Low battery alert
amber led on back PASS flashes every 10 seconds along with audible beep
Maximum working pressure
4500PSI
Air pressure gauge increments
1000lb increments from 0-6000
Sizes of air cylinders
45 min - 65.6 cubic feet
60 min - 87 cubic feet
When to change cylinder bottles
If below 4000lbs
When hydrostatic tested?
New and every 5 years
Life span of cylinder
15-30 years