Rx Trip / SI Actuation Signals Flashcards
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the Source Range Neutron Flux - High Rx Trip?
1x105 CPS [1/2]
Manual Block: > P-6 (IR > 1x10-10 amps [1/2])
Auto Block: > P-10 (PR > 10% [2/4])
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the Intermediate Range Neutron Flux - High Rx Trip?
25% RTP [1/2]
Manual Block: > P-10 (PR > 10% [2/4])
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the Power Range Neutron Flux - Low Rx Trip?
25% RTP [2/4]
Manual Block: > P-10 (PR > 10% [2/4])
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the Power Range Neutron Flux - High Rx Trip?
109% RTP [2/4]
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the Power Range Neutron Flux Positive Rate- High Rx Trip?
+4.25% / 2 Sec [2/4]
- Note: Must be manually reset on SE054 (NI Panel in back of control room)*
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the OTΔT Rx Trip?
122.6% (±) Penalties [2/4]
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the OPΔT Rx Trip?
110.73% (-) Penalties [2/4]
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the PZR Pressure - Low Rx Trip?
1885 PSIG [2/4]
Manual Block: >P-7 (P-10 or P-13 [1/2])
- P-10: PR > 10% [2/4]
- P-13: P > 10% Pimp [1/2]
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the PZR Pressure - High Rx Trip?
2385 PSIG [2/4]
- Reactor Trip Actuation Signals*
- *
What is the setpoint of the PZR Water Level - High Rx Trip?
92% [2/3]
Manual Block: >P-7 (P-10 or P-13 [1/2])
- P-10: PR > 10% [2/4]
- P-13: P > 10% Pimp [1/2]