Runaway Stabilizer Flashcards
Runaway Stabilizer
Condition: Uncommanded stabilizer trim movement occurs continuously or in a manner not appropriate for flight conditions
Condition: Uncommanded stabilizer trim movement occurs continuously or in a manner not appropriate for flight conditions.
Control column ….. Hold firmly
Control column ….. Hold firmly
Autopilot (If engaged) ….. Disengage
Autopilot (If engaged) ….. Disengage
Autothrottle (if engaged) ….. Disengage
Autothrottle (if engaged) ….. Disengage
Control column and thrust levers ….. Control airplane pitch attitude and airspeed
Control column and thrust levers ….. Control airplane pitch attitude and airspeed
Main Electric Stabilizer trim ….. Reduce control column forces
Main Electric Stabilizer trim ….. Reduce control column forces
If the runaway stops after the autopilot is disengaged:
- Do not re-engage the autopilot or autothrottle.
█ █ █ █
If the runaway stops after the autopilot is disengaged: Do not re-engage the autopilot or autothrottle. End of checklist
If the runaway continues after the autopilot is disengaged:
If the runaway continues after the autopilot is disengaged:
- STAB TRIM cutout switches (both) ….. CUTOUT
- STAB TRIM CUTOUT switches (both) ….. Cutout
- If the runaway continues:
- If the runaway continues:
– Stabilizer trim wheel ….. Grasp and hold