No firewall are allowed for low density residential uses;an abutment of up to_____ from establish grade level may however permitted but solely for the purpose of supporting the carport.
3.20 m
Eaves over required window shall not be less than _____ from the side and rear property lines.
750 mm
If only one RROW services a lot and such only 6.00-7.00 m wide a BHL____shall be observed
3 storey (9.00 m)
If only one RROW services a lot and such is only 4.00-5.00 m wide a BHL equivalent to______shall be observed
2 1/2 storey (7.50 m)
If only one RROW services a lot and such is only 3.00 m wide or less a BHL______shall be observed
2 storey ( 6.00 m )
Average automobile car parking diagonal and perpendicular
2.50 x 5.00 meters
Parallel parking dimension
2.15x 6.00
Standard truck or bus parking
3.60x12.00 meter
Articulated truck parking
3.60x18.00 meters
Multi floor parking garage may serve____parking requirement of the building within 200 meter radius
20%
Every dwelling shall be provided with at least _____ sanitary toilet
1 sanitary toilet
Footings shall be of sufficient size and strength and shall be at least_____ and _____ below the surface of the ground.
250 mm;600 mm
Live load for the first floor shall be_____
200 kg/sqm
Live load for the second floor
150 kg/sqm
Wind load for roofs shall be at least_____
120 kg/sqm